VERT-I-PAK

®

 A-SERIES

SINGLE PACKAGE 
VERTICAL AIR 
CONDITIONING SYSTEM

24,000 BTU/h

INSTALLATION & 
OPERATION GUIDE

Summary of Contents for VEA24K00 Series

Page 1: ...920 159 02 10 04 VERT I PAK A SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONINGSYSTEM 24 000 BTU h INSTALLATION OPERATION GUIDE...

Page 2: ...tion 9 Thermostat Control 12 10 Low Ambient Protection for Compressor Fan 12 11 Heating Defrost Heat Pump Models only 12 12 Fresh Air Door 13 13 Condensate Disposal System 13 IV Service Maintenance Wa...

Page 3: ...bery a clearance of 24 from the outdoor louver should be maintained For major obstructions such as a solid fence wall or other heat rejecting device like a condensing unit a mini mum distance of 72 sh...

Page 4: ...tors under unit Factory collar accepts 10 ex duct Section I General Speci cations VERT I PAK MODEL IDENTIFICATION GUIDE MODEL NUMBER V E A 24 K 50 RT A SERIES ELECTRIC HEATER SIZE A Series 00 No elect...

Page 5: ...x 23 deep x 47 1 4 high VPAWP1 8 1 14 Wall Plenum cut out dimensions 24 5 8 wide x 30 7 8 high VPRG4 Access Panel cutout dimensions 27 wide by 55 3 4 high See Figure 8 Page 10 for proper chassis inst...

Page 6: ...e outside wall plenum Part A Inside Wall Plenum Part B Wall Plenum Outdoor Louver Installation Rough opening dimension 24 5 8 wide x 30 7 8 high Ensure that the bottom of the plenum is 1 1 2 from the...

Page 7: ...2 4 K 7 5 V H A V E A 2 4 K 1 0 230 208 230 208 230 208 230 208 230 208 230 208 68 68 68 68 68 68 13 7 12 4 13 7 12 4 13 7 12 4 13 7 12 4 13 7 12 4 13 7 12 4 17 2 15 9 22 1 20 3 30 7 28 1 44 3 40 3 57...

Page 8: ...that branch circuit or general purpose outlet is grounded Wire Sizing Use recommended wire size given in tables and installasinglebranchcircuit Allwiringmustcomply with local and national codes NOTE...

Page 9: ...KW 2 5 KW 3 4 KW HEATER BLACK SEE NOTE 6 PRESSURE WHITE RELAY HEAT RELAY HEAT RELAY HEAT RELAY HEAT BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK BLACK RED RED RED RED RED RED RED RED 2 5KW 3 4KW 5...

Page 10: ...ccessories for installation details Return Air Grille Options Figure 9 VPRG2 Return Air Grille Unit requires a eld supplied access door or panel and a 16 x 20 lter VPRG4 Return Air Grille with Access...

Page 11: ...drain to the condensate exit location Be sure to use te on tape or approved pipe sealant on all drain connections and plugs see page 8 C Place the chassis into the closet with the outdoor side facing...

Page 12: ...callyswitchestoelectricheatduring defrost Whentheoutdoorambienttemperaturedropsbelowa45 F factory setting the chassis automatically switches to electric heat As outdoor ambient temperatures rise above...

Page 13: ...bly Maintenance can be accomplished easily by referring to the following directions However before performing any maintenance consider these important safety precautions WARNING ElectricalShockHazard...

Page 14: ...pany International Division Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part Reasonable proof must be presented to establish the date of insta...

Page 15: ...thermostat with one touch adjustment Mounts to wall for control of unit Same as VPAL2 but can be ordered in a special color to match the exterior wall ARCHITECTURAL LOUVER Extruded aluminum louver tha...

Page 16: ...ctory Certi ed Parts FRIEDRICH AIR CONDITIONING CO Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 Fax 210 357 4480 www friedrich c...