Friedrich VE09K50 Installation & Operation Manual Download Page 4

4

920-075-09

General Specifications

V

ert-I-Pak

®

 Model Identification Guide

Electrical Data

MODEL: 

V(E,H)A09

V(E,H)A12

 V(E,H)A18

Voltage (V)

230 / 208

230 / 208

230 / 208

Refrigerant

R-22

R-22

R-22

Chassis Width

23.125"

23.125"

23.125"

Chassis Depth

23.125"

23.125"

23.125"

Chassis Height **

32.25"

32.25"

32.25"

Shipping W x D x H

26.00" x 28.50" x 35.00"

26.00" x 28.50" x 35.00"

26.00" x 28.50" x 35.00"

Supply Duct Collar ***

10"

10"

10"

Drain Connection

3/4" FPT

3/4" FPT

3/4" FPT

Min. Circuit Amps

See Chassis Nameplate

CFM Indoor

See Charts 2 & 3 (Page 10)

Max. Duct ESP

.3 in. water

.3 in. water

.3 in. water

NOTES: 

 

**   Height includes 2" duct collar & isolators under unit.

*** Factory collar accepts 10" flex duct.

ELECTRIC HEATER SIZE

A Series

25 =   2.5 KW

34 =   3.4 KW

50 =   5.0 KW*

75 =   7.5 KW**

MODEL NUMBER 

V  E  A  09  K  34  RT  H

ENGINEERING CODE

OPTIONS

RT = Standard Remote Operation

*  Not available on 9000 BTU models.

** 24000 BTU only. 

VOLTAGE

K = 208/230V-1Ph-60Hz

 NOMINAL CAPACITY

A Series (Btu/h)

09 =   9,000

12 = 12,000

DESIGN SERIES

A = 32"/47" Cabinet

SERIES

V=Vertical Series

18 = 18,000

24 = 24,000

 E =Cooling with electric heat

 H =Heat Pump

Refer to electrical data chart for heater/unit compatibility.

 

Voltage ( V)  230/208  230/208  230/208  230/208  230/208  230/208  230/208  230/208  230/208 

 

LRA - Comp. (A) 

21 

21 

21 

24.0 

24.0 

24.0 

47 

47 

47

  Cooling Current (A)  4.4/4. 9  4.4/4. 9 

4.4/4.9 

5.5/6.1 

5.5/6.1  5.5/6.1  9.2/10.2  9.2/10.2  9.2/10.2

  MIN. Ckt. Amps (A) 

15 

20 

30 

15 

20 

30 

15 

20 

30

  Power Connection 

  HARD WIRED 

 

  HARD WIRED   

  HARD WIRED

V(E,H)A09K25V(E,H)A09K34V(E,H)09K50V(E,H)A12K25V(E,H)A12K34V(E,H,)A12K50V(E,H)A18K25

V(E,H)A18K50

V(E,H)A18K34

Model

Chassis Specifications

Important: all 208/230v chassis must be hard wired with properly sized breaker.  See nameplate for specific chassis 

electrical requirements. See page 8 - Figure 5 for unit wiring and wall thermostat wiring. See page 8 for wire size. Use 

HACR type breakers to avoid nuisance trips. All field wiring must be done in accordance with nec and local codes.

Summary of Contents for VE09K50

Page 1: ...920 075 09 11 07 VERT I PAK A SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONINGSYSTEM 9 000 18 000 BTU h INSTALLATION OPERATION GUIDE...

Page 2: ...d Thermostat Wiring Diagrams 11 Chassis Operation Fresh Air Door 12 Low Ambient Protection 12 Room Freeze Protection 12 Emergency Heat Override 12 Emergency Heat Operation 12 Service Servicing Chassis...

Page 3: ...louver should be maintained For major obstructions such as a solid fence wall or other heat rejecting device like a condensing unit a mini mum distance of 72 should be kept 12 24 60 VPAK VPAK VPAK POL...

Page 4: ...1Ph 60Hz NOMINAL CAPACITY A Series Btu h 09 9 000 12 12 000 DESIGN SERIES A 32 47 Cabinet SERIES V Vertical Series 18 18 000 24 24 000 E Cooling with electric heat H Heat Pump Refer to electrical dat...

Page 5: ...ge 7 for wire size Use HACR type breakers to avoid nuisance trips All field wiring must be done in accordance with NEC and local codes Sample Nameplate MODEL NO 1 SERIAL NO FRIEDRICH AIR CONDITIONING...

Page 6: ...ions 24 5 8 wide x 30 7 8 high VPRG4 Access Panel cutout dimensions 27 wide by 55 3 4 high See Figure 8 Page 10 for proper chassis installation Figure 3 Typical Utility Closet Chassis Shown in Closet...

Page 7: ...ide wall plenum Part A Inside Wall Plenum Part B Wall Plenum Outdoor Louver Installation Rough opening dimension 24 5 8 wide x 30 7 8 high Ensure that the bottom of the plenum is 1 1 2 from the floor...

Page 8: ...first stage increases energy efficiency utilizing a factory installed fan that slings the cold condensate onto the hot outdoor coil Part 2 When high outdoor humidity prevents the slinger from disposin...

Page 9: ...talled in accordance with the VPAWP1 8 1 14 Installation Manual B Place the chassis into the closet with the outdoor side facing the wall plenum opening C Slide the chassis into the wall plenum until...

Page 10: ...ol box and under the control components in the box to reach the connection terminal for the wiring 4 Make the wire connections appropriately matching the wires as the shown in the wiring diagram 5 Onc...

Page 11: ...09 NOTE THE DIAGRAM ABOVE ILLUSTRATES THE TYPICAL THERMOSTAT WIRING SEE THE UNIT CONTROL PANEL FOR THE ACTUAL UNIT WIRING DIAGRAM AND SCHEMATIC CONNECTION TERMINAL Electrical Thermostat Wiring Diagram...

Page 12: ...sh Air Door is an intake system The fresh air door is opened via a slide on the front of the chassis located just above the indoor coil Move the slide left to open and right to close the fresh air doo...

Page 13: ...f your Vert I Pak and allows lint and dirt to accumulate on the indoor air coil Lint and dirt on the indoor air coil can damage your unit and void the warranty The air filter should be replaced as it...

Page 14: ...coil Fan motor failure Restricted air flow Non condensables in refrigeration system 07 I D coil temperature 30 Deg F for 2 consecutive minutes Alternately flash set point and error code Continue fan o...

Page 15: ...pecial color to match the exterior wall ARCHITECTURAL LOUVER Extruded aluminum louver that attaches to the outdoor section of the wall plenum DIMENSIONS 31 1 16 high x 25 9 16 wide Same as VPAWP1 8 bu...

Page 16: ...n contact the Friedrich Air Conditioning Company International Division Any defective part to be replaced must be made available to FRIEDRICH in exchange for the replacement part Reasonable proof must...

Reviews: