HEATING LOAD FORM
FRIEDRICH ROOM UNIT HEAT PUMPS
BTU/HR PER
WALLS:
(Linear Feet)
°F TEMP. DIFFERENCE
2” Insulation
Lin. Ft. x 1.6
Average
Lin. Ft. x 2.6
WINDOWS & DOORS
(Area, sq. ft.)
Single Glass:
Sq. Ft. x 1.13
Double Glass:
Sq. Ft. x 0.61
INFILTRATION - WINDOWS & DOORS: AVG.
Lin. Ft. x 1.0
Loose
Lin. Ft. x 2.0
CEILING
: (Area, Sq. Ft.)
Insulated (6”)
Sq. Ft. x 0.07
Insulated (2”)
Sq. Ft. x 0.10
Built-up Roof (2” insulated
Sq. Ft. x 0.10
Built-up Roof (1/2” insulated)
Sq. Ft. x 0.20
No Insulation
Sq. Ft. x 0.33
FLOOR:
(Area, Sq. Ft.)
Above Vented Crawl space
Insulated (1:)
Sq. Ft. x 0.20
Uninsulated
Sq. Ft. x 0.50
* Slab on Ground
Lin. Ft. x 1.70
1” Perimeter insulation
Lin. Ft. x 1.00
* Based on Linear Feet of outside wall
TOTAL HEAT LOSS PER °F BTU/HR/°F
Multiply total BTU/HR/°F X 30 and plot on the graph below at 40°F. Draw a straight line from
the 70 base point thru the point plotted at 40°F. The intersection of this heat loss line with the
unit capacity line represents the winter design heating load.
62
Summary of Contents for Twintemp
Page 53: ...ELECTROMECHANICAL CONTROL COOL ONLY MODELS KS12L10 E F KS15L10 C D KM18L30 C D KM24L30 C D 51...
Page 54: ...ELECTROMECHANICAL CONTROL COOL ONLY MODELS SL28L30 D E SL36L30A D A E 52...
Page 55: ...ELECTROMECHANICAL CONTROL COOL WITH ELECTRIC HEAT MODEL EQ08L11A B A E 53...
Page 57: ...ELECTROMECHANICAL CONTROL COOL WITH ELECTRIC HEAT MODELS EL36L35A D A E 55...
Page 58: ...ELECTROMECHANICAL CONTROL HEAT PUMP ONLY MODELS YS09L10 F G 56...
Page 59: ...ELECTROMECHANICAL CONTROL HEAT PUMP WITH ELECTRIC HEAT MODELS YS13L33 D E YM18L34 D E 57...
Page 60: ...ELECTROMECHANICAL CONTROL HEAT PUMP WITH ELECTRIC HEAT MODELS YL24L35 E F 58...
Page 66: ......