En-9

ADJUSTING THE DIRECTION OF AIR CIRCULATION

 

 Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Control Unit.

  Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow-direction louvers have

stopped moving.

 

R

 

DANGER!

Never place fingers or foreign objects in-
side the outlet ports, since the internal fan
operates at high speed and could cause
personal injury.

Always use the Remote Control Unit’s

SET button to adjust the vertical airflow

louvers. Attempting to move them

manually could result in improper op-

eration; in this case, stop operation and

restart. The louvers should begin to
operate properly again.

During Cooling and Dry modes, do not

move the vertical air direction louvers

outside their proper operating range
for the mode (

1

 - 

3

) and into the fan

region (

4

 - 

6

); using the louvers in

the fan region will cause moisture to

condense near the air outlet, and wa-

ter may drop onto the floor. During the

Cooling/Dry modes, if the louvers are

operated outside the range 

1

 - 

3

 for

more than 30 minutes, they will be

automatically returned to the 

3

 range.

When used in a room with infants, chil-

dren, elderly or sick persons, the air

direction and room temperature

should be considered carefully when
making settings.

Vertical Air Direction Adjustment

Press the SET button (Vertical) (Fig. 6 

Q

).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

6

Types of Air flow Direction Setting:

1

,

2

,

3

 :

During Cooling/Dry modes

1

,

2

,

3

,

4

,

5

,

6

 :

During Fan mode

The Remote Control Unit’s display does
not change.

Use the air direction adjustments within the ranges shown above.

The vertical airflow direction is set automatically as shown, in accordance with
the type of operation selected.

During Cooling/Dry mode : Horizontal flow 

1

During Fan mode

: Downward flow 

5

During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal 

1

; the air direction cannot be adjusted during this pe-

riod.

Direction 

1  2

Only the direction of the Air Flow Direction Louver changes; the direction of the
Power Diffuser does not change.

1
2
3
4

5

6

Horizontal Air Direction Adjustment

Press the SET button (Horizontal)(Fig. 6 

R

).

Each time the button is pressed, the air direction range will change as follows:

1

 

 

2

 

 

3

 

 

4

 

 

5

1

2

3

4

5

The remote control unit’s
display does not change.

Summary of Contents for MR24C3F

Page 1: ...an ais Espa ol Indoor Unit MW24C3F MW30C3F MW36C3F Outdoor Unit MR24C3F MR30C3F MR36C3F INVERTER COOLING MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Friedrich Air Conditioning Co 4200 N Pan Am San An...

Page 2: ...paratus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner DANGER CAUTION En 1 OPERATION TIMER SUPER QUIET...

Page 3: ...matically turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation HORIZONTAL AIRFLOW For cooling use horizontal airflow so the c...

Page 4: ...smit Indicator Y Clock Display Z Operating Mode Display Timer Mode Display Fan Speed Display Temperature SET Display SLEEP Display a SWING Display Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 M...

Page 5: ...direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST b...

Page 6: ...a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 O Each time the button is pressed the fan speed changes in the follow...

Page 7: ...tion Cooling to adjust the temperature to the value set in the thermostat The monitor operation range is 4 F relative to the thermostat set ting If the mode automatically selected by the unit is not w...

Page 8: ...conds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one trans...

Page 9: ...ing during sleep the SLEEP timer function automatically modifies the thermostat setting in accord ance with the set time setting When the set time has elapsed the air conditioner completely stops Duri...

Page 10: ...e automatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Ve...

Page 11: ...rding to the current airflow direc tion Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizontal position the lower airflow direction louver moves swings to d...

Page 12: ...lle 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of exam...

Page 13: ...itted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted...

Page 14: ...erly OPERATING TIPS If the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or o...

Page 15: ...lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air ci...

Page 16: ......

Page 17: ......

Page 18: ......

Reviews: