background image

(1) Cut a 3-2/16’’(80 mm) diameter hole in the wall at the position shown

in (Fig.1).

(2) When cutting the wall hole at the inside of the wall hook bracket,

cut the hole within the range of the left and right center marks
3/8’’(10 mm) below the installation frame.

     When cutting the wall hole at the outside of the wall hook bracket,

cut the hole at least 3/8’’(10 mm) below less.

(3) Cut the hole so that the outside end is lower 3/16’’ to 3/8’’ (5 to 10 mm)

than the inside end.

(4) Always align the center of the wall hole. If misaligned, water leak-

age will occur.

(5) Cut the wall pipe to match the wall thickness, stick it into the wall

cap, fasten the cap with vinyl tape, and stick the pipe through the
hole. (The connection pipe is supplied in the installation set.)
(Fig.1)

(6) For left piping and right piping, cut the hole a little lower so that

drain water will flow freely. (Fig.1)

Fig. 1

(1) Install the wall hook bracket so that it is correctly positioned hori-

zontally and vertically. If the wall hook bracket is titled, water will
drip to the floor.

(2) Install the wall hook bracket so that it is strong enough to with-

stand the weight of an adult.

Fasten the wall hook bracket to the wall with 6 or more screws
through the holes near the outer edge of the bracket.

Check that there is no rattle at the wall hook bracket.

Fig. 2

4.

CONNECTING THE PIPING

For left piping and left rear piping, align the marks on the wall
hook bracket and shape the connection pipe.

Bend the connection piping at a bend radius of 2 - 3/4’’(70 mm) or
more and install no more than 1- 3/8’’(35 mm) from the wall.

After passing the indoor piping and drain hose through the wall
hole, hang the indoor unit on the hooks at the top and bottom of
the wall hook bracket.

[Installing the indoor unit]

Hang the indoor unit from the hooks at the top of the wall hook
bracket.

Insert the spacer, etc. between the indoor unit and the wall hook
bracket and separate the bottom of the indoor unit from the wall.

Fig. 4

After hooking the indoor unit to the top hook, hook the fittings of the
indoor unit to the two bottom hooks while lowering the unit and
pushing it against the wall.

Top hooks

Indoor unit

(Fitting)

Bottom hooks

Wall hook
bracket

Indoor unit

Wall hook bracket

(Spacer)

CONNECTION

(1) Install the outdoor unit wall cap (supplied with the optional in-

stallation set or procured at the site) to the wall pipe.

(2) Connect the outdoor unit and indoor unit piping.
(3) After matching the center of the flare surface and tightening the

nut hand tight, tighten the nut to the specified tightening torque
with a torque wrench. (Tighten the flare nut of the outdoor unit
3-way valve after air purging.)

FLARING

(1) Cut the connection pipe to the necessary length with a pipe cutter.
(2) Hold the pipe downward so that cuttings will not enter the pipe

and remove the burrs.

(3) Insert the flare nut onto the pipe and flare the pipe with a flaring

tool.

Check if [L] is flared uniformly
and is not cracked or scratched.

L dimension
Thin pipe

1/4” (6.35 mm)dia. ...... 1/16” (1.4 to 1.7 mm)

Thick pipe 1/2” (12.7 mm)dia. ...... 5/64” (1.9 to 2.2 mm)

Flare nut

1/4” (6.35 mm)dia.

1/2” (12.7 mm)dia.

Tightening torque

11.57 to 13.02 ft•lbs

(160 to 180 kgf•cm)

36.17 to 39.78 ft•lbs

 (500 to 550 kgf•cm)

Table 2

Flare nut tightening torque

Fig. 5

Tighten with two wrenches.

Torque wrench

Wrench (fixed)

Flare nut

Indoor unit pipe

Connection pipe

To prevent gas leakage,
coat the flare surface
with refrigerator oil.

Connection pipe
(1/4” (6.35 mm) dia.)

Connection pipe

(1/2’’(12.7 mm) dia.)

Align the marks.

Bend 2-3/4’’(R70)
with a pipe bender

BENDING PIPES

The pipes are shaped by your hands. Be careful not to collapse them.

Do not bend the pipes in an angle more than 90°.
When pipes are repeatedly bent or stretched, the material will harden,
making it difficult to bend or stretch them any more. Do not bend or stretch
the pipes more than three times.

OK

NO

Extend the pipe
by unwinding it.

2.

 INSTALLING THE WALL HOOK BRACKET

INDOOR UNIT

1.

 CUTTING THE HOLE IN THE WALL FOR THE CONNECTING PIPING

3.

 FORMING THE DRAIN HOSE AND PIPE

Wall hook
bracket

Counter weight

Wall hook bracket

Tapping screw

Center notch

String

Hook

 CAUTION

Install the wall hook bracket horizontally and perpen-
dicularly.

 WARNING

If the wall pipe is not used, the cord interconnecting
the indoor and outdoor units may touch metal and
cause electric leakage.

Fasten with
vinyl tape

(Wall cap)

(Wall pipe)

(Inside)

Wall

(Outside)

Lower

3-2/16’’(80 mm)
dia. hole

Center mark

3/8’’(10 mm)
or over

3/16’’ to 3/8’’
(5 to 10 mm)
low

3/8’’(10 mm)
or over

Lower

3-2/16’’(80 mm) dia. hole
(A 2-9/16’’(65mm)
diameter hole is
possible for the right-
hand side.)

[Rear piping, Right piping, Bottom piping]

Install the indoor unit piping in the direction of the wall hole and
bind the drain hose and pipe together with vinyl tape. (Fig. 3)

Install the piping so that the drain hose is at the bottom.

Wrap the pipes of the indoor unit that are visible from the outside
with decorative tape.

[For Left rear piping, Left piping]

Interchange the drain cap and the drain hose.

Fig. 3

Drain cap

Indoor unit
drain hose

Remove the drain cap by pulling
at the projection at the end of
the cap with pliers, etc.

For left outlet piping, cut off the
piping outlet cutting groove
with a hacksaw.

Right piping

Bind with vinyl tape

Indoor unit drain hose
(bottom)

Pipe (top)
Rear piping

Bottom

piping

Removal method of drain
hose

Remove the screw at the left of
drain hose and pull out drain
hose.

Installation method of
drain hose

Vertically insert the drain hose
toward the inside, so that the
drain fixture (blue) can accu-
rately align with the screw hole
around the drain cock.
After inserting and before re-
placing, please reinstall and fix
the removed screws.

●   

Be sure to install around the drain hose connector.

●   

As the screw is inside, be sure to use screwdriver treated with magnet.

Screw

Drain hose

Drain fixture
(blue)

Screw hole

Drain hose

Screw

Drain cock

Drain fixture (blue)

 CAUTION

(1)

  

In order to align the drain hose and drain cap, be

sure to insert securely and vertically. Incline in-
sertion will cause water leakage.

(2)

  

When inserting, be sure not to attach any mate-
rial besides water. If any other material is attached,
it will cause deterioration and water leakage.

(3)

  

After removing drain hose, be sure not to forget
mounting drain cap.

(4)

  

Be sure to fix the drain hose with tape to the bot-

tom of piping.

(5)

  

Prevent drain water frozen under low tempera-
ture environment.

When installing indoor unit's drain hose outdoors,
necessary measure for frost protection should be
taken to prevent drain water frozen.

  

 Under low temperature environment (when out-

door temperature under 32 °F), after cooling op-
eration is executed, water in the drain hose could
be frozen.
Once drain water is frozen, the drain hose will
be blocked and water leakage may be resulted
for indoor unit.

 CAUTION

(1) Fasten a flare nut with a torque wrench as instructed in this manual. If

fastened too tight, the flare nut may be broken after a long period of time
and cause a leakage of refrigerant.

(2) During installation, make sure that the refrigerant pipe is attached firmly

before you run the compressor. Do not operate the compressor under the
condition of refrigerant piping not attached properly with 2-way or 3-way
valve open. This may cause abnormal pressure in the refrigeration cycle
that leads to breakage and even injury.

Summary of Contents for MR18C3F

Page 1: ...re the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to walls and floors In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid level foundation fo...

Page 2: ...e shaped by your hands Be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly bent or stretched the material will harden making it difficult to bend or stretch them any more Do not bend or stretch the pipes more than three times OK NO Extend the pipe by unwinding it 2 INSTALLING THE WALL HOOK BRACKET INDOOR UNIT 1 CUTTING THE HOLE IN THE WALL FOR T...

Page 3: ...ssories are supplied Use them as required INDOOR UNIT ACCESSORIES Connection pipe assembly Connection cord 3 conductor Wall pipe Decorative tape Vinyl tape Wall cap Saddle Drain hose Tapping screws Sealant Name Q ty 1 1 1 1 1 1 1 set 1 1 set 1 ELECTRICAL REQUIREMENT Always make the air conditioner power supply a special branch cir cuit and provide a special switch and receptacle Do not extend the ...

Page 4: ... with local codes while run ning the wire from the indoor unit to the out door unit size of wire and wiring method etc Every wire must be connected firmly No wire should be allowed to touch refrigerant tubing the compressor or any moving part Loose wiring may cause the terminal to over heat or result in unit malfunction A fire hazard may also exist Therefore be sure all wiring is tightly connected...

Page 5: ...r wire cutting pliers then strip the insulation to about 15 16 25 mm to expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using pliers bend the solid wire to form a loop suitable for the termi nal screw 4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw using a screwdriver B For strand wiring 1 Cu...

Page 6: ...ir conditioner is run by pressing the test run button the OPERATION indicator lamp and TIMER indicator lamp will simultaneously flash slowly 1 INDOOR UNIT 1 Is operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do the air flow direction louver operate normally 4 Is the drain normal 2 OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation...

Page 7: ...t be affected by the heat from a stove etc 1 REMOTE CONTROL UNIT HOLDER INSTALLATION Install the remote control unit with a distance of 23 ft 7 m between the remote control unit and the photocell as the criteria However when installing the remote con trol unit check that it operates positively Install the remote control unit holder to a wall pillar etc with the tapping screw Fig 20 Remote control ...

Reviews: