Friedrich M09CH Installation And Operation Manual Download Page 12

13

TEMP:

ambient temperature, 5s later or within 5s, it receives other remote control signal that will 
return to display the setting temperature. if the users haven't set up the temperature 
displaying status,that will display the setting temperature.(This function is not applicable 
for some models).

TIMER ON :

TIMER OFF :

11

10

TURBO:

12

Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply

press this button again.

After 

pressing 

this  button,       disappears and "ON "blinks 

                          . 00:00 is displayed for ON time

setting. Within 5 seconds, press + or - button to adjust the time value. Every press of either

button changes the time setting by 1 minute. Holding down either button rapidly changes the

time setting by 1 minute and then 10 minutes.  Within 5 seconds after setting, press TIMER

ON button to confirm. 

Press this button to set  up & down swing angle, which circularly changes as below:

OFF

This remote controller is universal. If any command        ,           or          is sent out,

the unit will carry out the command as

       

indicates the guide louver swings as:

fan will continue operation for 10 min utes in order to dry the indoor unit even though you 
have  turned off the unit.

HEAT mode.  

Press this button to activate / deactivate the Turbo function which enables the unit to

reach the preset temperature in the shortest time. In COOL mode, the unit will blow strong
cooling air at super high fan speed. In HEAT mode, the unit will blow strong heating air
at super high fan speed. (This function is not applicable for some models).

Press this button to initiate the auto-off timer. To cancel the auto-timer program, simply 

press the button again.TIMER OFF setting is the same as TIMER ON. 

9

8

AIR SWEEP:

EXTEND:

Pressing 

 button in COOL or DRY mode, the icon      is displayed and the indoor

After energization, 

OFF is defaulted. 

 is not available in  AUTO, FAN or  

EXTEND

EXTEND

EXTEND

Remote Control Instructions

 the indoor setting temperature or indoor ambient 

By pressing this button you can display

temperature.When the indoor unit 

 it will display the setting temperature, 

is first powered on

if the temperature's display  status is changed from other status to"    ",displays the 

8

Summary of Contents for M09CH

Page 1: ...Models Indoor Unit Outdoor Unit MW09C1H MW12C1H MR09C1H MR12C1H 920 088 01...

Page 2: ......

Page 3: ...ance Children should be supervised to ensure that they do not play with the appliance Image shown in this operating instruction manual here is indicative only Actual product you receive may differ Tha...

Page 4: ...chanic Code 2009 or current edition and any other applicable local or national codes Failure to do so can result in property damage personal injury or death WARNING Refrigeration system under high pre...

Page 5: ...will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments When outdoor temperature is low but high humidity after a long...

Page 6: ...the low temperature The operating temperature range outdoor temperature for cooling unit is 32 115 for cooling and heating unit is 5 115 Working temperature range Maximum cooling Minimum cooling Maxim...

Page 7: ...i t c e n n o C Air inlet Image shown here is indicative only Actual product you receive may differ Front Panel Air outlet Filter Guide panel Wireless remote control Set temp Heating Display icon Onl...

Page 8: ...t auto on timer Press it to set auto off timer Press it set clock 1 6 7 5 3 2 4 11 10 14 9 12 13 15 Operation of Remote Controller 3 9 10 13 12 5 4 11 8 7 2 1 6 8 Press it to turn on off the light Pre...

Page 9: ...l show 18 is displayed when pressing display After pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display Pressing TEMP button set temperature ambient temperature...

Page 10: ...d High Your selection will be displayed in the LCD windows except the AUTO fan speed FAN SPEED display is displayed when pressing the to clear the display Operation of Remote Controller icon SENSOR ic...

Page 11: ...AUTO mode is defaulted In AUTO mode the set temperature will not be displayed on the LCD and the unit will automatically select the suitable operation mode in accordance with the room temperature to m...

Page 12: ...unit will carry out the command as indicates the guide louver swings as fan will continue operation for 10 min utes in order to dry the indoor unit even though you have turned off the unit HEAT mode...

Page 13: ...replacing batteries Replacement of Batteries Press and buttons simultaneously to lock or unlock the keypad If the remote controller is locked is pressing any button blinks three times SLEEP LIGHT 16...

Page 14: ...ontrol of indoor unit the light function the mark will To turn On the light function the will To turn Off disappear on the remote controller screen by pressing this button In which case the display in...

Page 15: ...ther use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can Insert the a...

Page 16: ...re setting Unit will resume normal operation once power has been restored Clean air filter Clean air conditioner Please contact an Authorized Friedrich Service Agency When the compressor starts or sto...

Page 17: ...13...

Page 18: ...ere is harsh sound during operation The terrible odors emitted during operation Water is leaking in the room Air switch or protection switch often breaks There is an abnormal heat in power supply cord...

Page 19: ...Service Assistance Troubleshooting section and still need help here is a list of available services 1 2 3 15...

Page 20: ...6 3 Select a location where the children can not reach 7 8 9 Important Notices The air inlet and outlet vent should be far from the obstruction make sure that the air can be blown through the whole r...

Page 21: ...fixed wiring It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have the functions o...

Page 22: ...ove Above Above Above Above The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction...

Page 23: ...g damaged when passing through the hole Install the water drainage pipe 1 For well draining the drain hose should be placed at a downward slant 2 Do not wrench or bend the drain hose or flood its end...

Page 24: ...s 2 when routing both the wiring and piping Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 8 Hange the mount...

Page 25: ...ction cable with wire clamp for cooling and heating unit use the wire clamp to fix the power connection cable and the signal control wire then connect the corresponding Ensure wire has been fixed well...

Page 26: ...art Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit been connected to a secure earth connection It may c...

Page 27: ......

Page 28: ...Friedrich Air Conditioning Co 10001 Reunion Place Suite 500 San Antonio Texas 78216 1 800 541 6645 www friedrich com 66129907272...

Reviews: