![Friedrich CP06E10 Service And Parts Manual Download Page 18](http://html1.mh-extra.com/html/friedrich/cp06e10/cp06e10_service-and-parts-manual_2333113018.webp)
3. CAPACITOR
MODEL : R1003Y4
MODEL : BG8000ER, WG8000RY4, WG1000RY4
4. THERMOSTAT
MODEL : R1003Y4
Disassembly
18 Room Air Conditioner
1. Remove the control box.
2. Remove the screw which fasten control panel from
control box.
3. Remove the screw which located in the front.
4. Open the bottom side of control box.
5. Remove the screw and the clamp which fastens
the capacitor.
6. Disconnect all the leads of capacitor terminals.
7. Re-install the components by referring to the
removal procedure, above. (See Figure
27
)
Figure
27
Figure
26
1. Remove the control box.
2. Remove the knobs and the screw which fasten
control panel from control box.
3. Remove the screw which is located in the front.
4. Open the bottom side of control box.
5. Remove the screw and the clamp which fasten the
capacitor.
6. Disconnect all the leads of capacitor terminals.
7. Re-install the components by referring to the
removal procedure, above. (See Figure
26
)
1. Remove the control box.
2. Open the control box.
3. Remove the 2 screws which fasten the thermostat.
4. Disconnect 2 leads of thermostat terminals.
5. Remove the thermostat.
6. Re-install the components by refereing to the above
removal procedure. (See Figure
28
)
Figure
28