FRIEDLAND SPECTRA 140 Instruction Manual Download Page 8

TROUBLESHOOTING GUIDE

5

Cover the Detector lens completely with thick cloth or a piece of cardboard to 
prevent it ‘seeing’. If the unit now switches off after the set time duration,
there has been interference from some source within range. Adjust the tilt and
swivel head or mask off the required area of lens [see Section 1] to avoid the
interference. Sometimes strong winds, passers-by, road traffic, small animals
or pets can trigger the PIR. Mask or reposition the unit if necessary.

Thoroughly check that your wiring is correct according to the wiring diagram.
Be sure you allow the unit to complete its warm-up period - stay well out of the
detection area and wait [warm-up should never take longer than 5 minutes].

Check power is ON. If so, turn power OFF and check wiring is correct, and that
no connections are loose. Check that lamps in the system have not failed, and
that they are properly seated in their holders.

Ambient light level may be too high in operational area. Adjust the LUX control
slowly clockwise until lamp illuminates [See Section 4 for details].

Ambient light level may be too low in operational area. During daylight, turn the
LUX control slightly anti-clockwise. When lamp extinguishes, enter detection
area, if PIR still activates, adjust LUX further in anti-clockwise direction and
enter the detection zone again. Repeat procedure until PIR does not activate
[See Section 4 for details].

Check suitability of location - see Section 1 for advice, and reposition PIR if
necessary.

The PIR Detector operates by sensing body heat. On cold evenings, the Detector
more easily ‘sees’ body heat; in warm weather, the opposite is true. For this
reason, in some cases it may be necessary to make small seasonal adjustments
to the Detector’s head position, for trouble-free year round operation.

REMEMBER Always ensure the mains supply to the unit is isolated before
removing covers which allow access to live parts.

Light stays ON all the
time at night, or PIR
activates for no reason
at random

Light stays ON all the
time day and night

PIR Detector will not
operate at all

The PIR Detector will
not operate at night

Unit activates in 
daytime

PIR coverage is
poor/sporadic

Detection range
changes from day 
to day

PROBLEM SOLUTION

8

L210S 6017 ENG 1-10  8/15/06  10:10 AM  Page 10

Summary of Contents for SPECTRA 140

Page 1: ...t person e g a qualified electrician in accordance with these instructions and in accordance with the appropriate clauses of the current edition of the IEE wiring regulations BS7671 DANGER 240 VOLTS T...

Page 2: ...Fig 3 So if possible mount the PIR facing ACROSS the approach to your property Fig 1 Fig 2 Fig 3 False activation reduction technology makes your PIR Detector less prone to activation by wind rain mov...

Page 3: ...drill the holes to the required depth and insert the wall plugs Cabling can either be from directly behind the unit through the wall or along the surface from below via the gaps provided in the housi...

Page 4: ...It is suggested that 3 core round flexible cable of at least 1mm2 gauge is used It is also allowable for the unit to be connected to the domestic socket ring main though it is suggested that a 5 amp f...

Page 5: ...TH NEUTRAL OPERATION 4TESTING Walk Testing When the installation procedure is complete the unit is ready for testing The Walk Test procedure is as follows Step 1 Set the two adjustment controls on the...

Page 6: ...to establish the detection pattern Step 6 If the detection area is too small for your requirements try angling the sensor head up This should increase the coverage distance Similarly angling the head...

Page 7: ...s giving a total ON time of 3 minutes all timings are approximate Step 2 The LUX control determines the level of darkness required for the unit to start operating each evening The setting is best achi...

Page 8: ...ee Section 4 for details Ambient light level may be too low in operational area During daylight turn the LUX control slightly anti clockwise When lamp extinguishes enter detection area if PIR still ac...

Page 9: ...onds 15 minutes Lux Level Adjustment Day night or night only operation Environmental Protection IP44 Suitable for outdoor use The PIR sensor emits no radiation is not harmful to people animals or plan...

Page 10: ...arantee will be invalidated The guarantee states Novar ED S entire liability It does not extend to cover consequential loss or damage or installation costs arising from the defective product This guar...