PLEASE REFER TO YOUR SYSTEM INST
ALLATION
& OPERATING INSTRUCTION MANUAL FOR FULL
CONNECTION DETAILS.
1. Remove one of the cable entry cut-outs on the Contact
Switch and feed the cable through the entry into the
Contact Switch housing.
2. Carefully remove the outer sheath of the cable and then
strip 5mm of insulation from the Yellow and Blue wires.
Connect the Yellow and Blue wires to the Contact
Switch terminals as shown.
3. Strip off 5 mm of the insulation from the Green and
White wires and connect together using a spare terminal
in the contact housing.
Note: If the spar
e contact terminals are not present in
the contact then the ends of the wires should be
securely twisted (or soldered) together and insulated.
If connecting multiple contacts the Tamper circuit wiring
should be continued in a series loop in a similar way to
the zone wiring.
Note: If your existing system is using a non-standar
d colour
coding system for the wiring, then this must be followed.
4. The remaining wires should be trimmed back and
insulated to prevent short circuits and then tucked away
in the Contact Switch housing.
5. Fix the Contact Switch to the fixed part of the
door/window frame immediately beside the Magnet
using two 25mm Counter-sunk fixing screws.
Ensure that the parallel gap between the Magnet and
Contact Switch positions is no greater than 9mm.
6. The Magnetic contact is now ready to be connected to
the Control Panel or existing zone wiring.
If wiring the new Magnetic contact to an unused zone
connect to the appropriate zone terminals. Alternatively
if wiring into a zone with which already has a detector,
the contact wiring from the new Contact Switch must be
connected in a SERIES loop with existing zone wiring.
The Tamper circuit wiring from the new Contact Switch
must be incorporated into the existing tamper circuit in
a SERIES loop.
7. The Magnetic contact is now ready to be tested.
T
esting the Magnetic Contact
Once the Magnetic Contact has been installed, r
econnect
the power to the alarm system and test the new Magnetic
Contact and the system in accordance with the System
Installation & Operating Manual.
Note: After r
econnecting the power to the system allow at
least 4 minutes for any PIR(s) to stabilise before testing.
SINGLE CONTACT
WHITE
BLUE
GREEN
YELLOW
Note: If spare terminals
are not present in the
Contact Switch, ends of
wires should be twisted
(or soldered) together
and insulated.
WHITE
BLUE
YELLOW
GREEN
MULTIPLE CONTACTS
Wired in series
HELPLINE
If you have a pr
oblem with your alarm,
please call the helpline on:
45169PL Ed.2
Friedland, Novar Electrical Devices and Systems.
The Ar
nold Centre, Paycocke Road, Basildon, Essex SS14 3EA.
0
1268 563273
(Lines open 9.00am to 5.00pm, Monday to Friday).
Guarantee
Novar ED&S under
takes to replace or repair at its discretion goods (excluding non rechargeable batteries) should they become defective within
1 year solely as a result of faulty materials and workmanship.
Understandably if the product has not been installed, operated or maintained in accordance with the instructions, has not been used appropriately
or if any attempt has been made to rectify, dismantle or alter the product in any way the guarantee will be invalidated.
The guarantee states Novar ED&S entire liability. It does not extend to cover consequential loss or damage or installation costs arising from the
defective product. This guarantee does not in any way affect the statutory or other rights of a consumer and applies to products installed within the
UK and Eire only.
If an item develops a fault, the product must be returned to the point of sale with:
1. Proof of purchase. 2. A full description of the fault. 3. All relevant batteries (disconnected).
Friedland is a trade mark of Novar ED&S.
© Novar ED&S, 2004