AD Corinte A/E - ADCS

.

... 26

GB  

.

... 23

SE  

.

... 29

RU  

Summary of Contents for Thermozone AD Corinte A - ADCS

Page 1: ...AD Corinte A E ADCS 26 GB 23 SE 29 RU ...

Page 2: ...orinte A E ADCS 2 Min 180 M8 116 72 125 225 M8 116 72 125 225 Min 180 Cu ø22 VL A VL B VR A VR B Fig 1 Upper part of the unit seen from above Bottom part of the unit seen from above Opening Connection hatch ...

Page 3: ...AD Corinte A E ADCS 3 1 2 80 60 1 2 60 80 3 Ø22 Cu 2200 2450 500 350 Fig 2 ...

Page 4: ...AD Corinte A E ADCS 4 1 2 3 4 5 6 7 8 9 10 A B C Fig 3 ...

Page 5: ...AD Corinte A E ADCS 5 Fig 4 ...

Page 6: ...AD Corinte A E ADCS 6 80 35 ø12 180 35 25 40 Fig 6 Fig 7 360 243 Ø22 Ø10 15 5 10 Fig 5 ...

Page 7: ...AD Corinte A E ADCS 7 1700 2200 1666 2166 75 Ø30 Ø20 3x Left connection Right connection Wall Fig 8 Fig 9 50 75 376 ADCS E Min 220 mm ADCS A W Min 180 mm ADCS E Min 220 mm ADCS A W Min 180 mm ...

Page 8: ...AD Corinte A E ADCS 8 Fig 10 SIRe ...

Page 9: ...AD Corinte A E ADCS 9 A B C A C B ADCEH Ø8 Ø12 2x 2 alternatives for securing at the top 1 Ø8 for securing at the air curtain 2 ...

Page 10: ...Description HxWxD mm L m SIReB Control system Basic SIReAC Control system Competent SIReAA Control system Advanced SIReRTX 673 09 22 External room temperature sensor 70x33x23 SIReUR 673 09 21 Kit for recessed installation 114x70x50 SIReWTA Clamp on sensor SIReCJ4 Joint piece for two pcs RJ11 4p 4c SIReCJ6 Joint piece for two pcs RJ11 6p 6c SIReCC603 673 09 23 Modular cable RJ11 6p 6c 3 SIReCC605 6...

Page 11: ...ernal ADCS A ADCSA SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L N ...

Page 12: ...IRe Basic SIRe Basic Parallel connection C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY 230V SIReB1 SIReUB1 C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY 230V 230V SIReB1 SIReB1 SIReUB1 ...

Page 13: ...CK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 ROOM C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE 230V SIReB1 SIReC1X SIReDC SIReUA1 ...

Page 14: ... L PE N L PE ACTUATOR SUPPLY Pot Unit ID Pot Unit ID EXTERNAL SETBACK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM 230V 230V 230V SIReB1 SIReB1 SIReB1 SIReC1X SIReDC SIReUA1 ...

Page 15: ...3 ADCSE 400V3 400V3 SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Black Grey Blue Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L N ...

Page 16: ...3 ADCSE 230V3 230V3 SIReB1 230V Actuator 230V Transformer 230V 200V 170V 145V 120V 100V N Black Black Grey Blue Blue Supply 230V C2 C1 ROOM Internal sensor Motor protection Transformer 230V 200V 170V 145V 120V 100V N Yellow Orange Red Brown Black Green Blue L1L2 ...

Page 17: ...230V C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY Wiring diagrams AD Corinte E Electrical control options SIRe Basic SIRe Basic Parallel connection SIReB1 SIReB1 SIReB1 SIReRTX optional SIReRTX optional SIReUB1 SIReUB1 ...

Page 18: ...XTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 ROOM C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE 230V Wiring diagrams AD Corinte E Electrical control options SIReAC Competent SIReB1 SIReC1X SIReRTX optional SIReDC SIReUA1 ...

Page 19: ...TUATOR SUPPLY Pot Unit ID Pot Unit ID EXTERNAL SETBACK TEMP ON OFF potential free contact EXTERNAL ALARM IN potential free contact EXTERNAL RPM 0 10V DC IN EXTERNAL ON OFF 5 30V AC DC ALARM OUT BMS potential free contact max 3A 230V 7 8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM 230V 230V 230V SIReAC Competent Parallel connection SIReB1 SIReB1 SIReB1 SIReC1X SIReRTX optional SIReDC SIReUA1 ...

Page 20: ...8 9 10 1112 15 161718 19 20 COM 1 COM 2 BUS ROOM C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE BMS INDICATION OUT potential free contact max 3A 230V 1 2 3 4 5 6 13 14 RPM INDICATION 0 10V DC out max 5 mA EXTERNAL HEAT 0 10V DC IN 21 22 HEAT INDICATION 0 10V DC out max 5 mA ACTUATOR SUPPLY 230V Wiring diagrams AD Corinte E Electrical control options SIReAA Advanced SIReB1 SIReA1X SIReRTX optional S...

Page 21: ...OUT potential free contact max 3A 230V 1 2 3 4 5 6 13 14 RPM INDICATION 0 10V DC out max 5 mA EXTERNAL HEAT 0 10V DC IN 21 22 HEAT INDICATION 0 10V DC out max 5 mA C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY C2 X5 C1 X4 ROOM X3 Pot Unit ID N L PE N L PE ACTUATOR SUPPLY Pot Unit ID Pot Unit ID 230V 230V 230V SIReAA Adva...

Page 22: ...cations Thermozone AD Corinte A without heat 1 Type Output kW Airflow m3 h Sound level 5 dB A Output motor W Voltage motor V Amper age motor A Length mm Weight kg ADCS17A 0 1400 3000 40 60 670 230V 2 9 1700 73 ADCS22A 0 1800 4000 42 61 990 230V 4 3 2200 95 ADCS25A 0 2050 4500 43 63 1150 230V 5 0 2450 108 ADCS17 is available only for horizontal mounting ADCS25 is available only for vertical mountin...

Page 23: ...ompleted Take care not to damage the surfaces For optimal performance it is recommended that a minimum gap of 220 mm to the ceiling General instructions Read these instructions carefully before in stallation and use Keep this manual for future reference The guarantee is only valid if the Thermo zone units are used in the manner intended by the manufacturer and in accordance with the Frico installa...

Page 24: ...ide the unit when con nected from below Secure the wiring inside the unit with cable ties to prevent it being sucked into the fans or in contact with the heating elements The control system is pre installed in the aircurtain with an integrated control card see fig 8 SIRe is supplied pre programmed with quick release connections Modular cables are connected to the con trol board Base by opening the...

Page 25: ... this may be due to moisture in the heating ele ment When an appliance containing a heater element has not been used for a long period or stored in a damp environment moisture can enter the element This should not be seen as a fault but is simply rectified by connecting the appliance to the mains supply via a socket without a safety cut out so that the moisture can be eliminated from the element T...

Page 26: ...B Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se Art no 208032 2013 04 05 HH SÄ ...