Frico Thermozone AC 400 Quick Start Manual Download Page 11

Thermozone AC 400

Type

AC401

AC402

AC412

AC418

Power

[kW]

0,6

1,0

12

18

Voltage, motor / manouvre

[V]

230~

230~

230~

230~

Voltage, heat output

[V]

-

-

400V3~

400V3~

Voltage, motor / manouvre

[A]

2,6

4,3

2,5

4,3

Amperage heat output

[A]

-

-

17,3

26,0

Air flow

[m

3

/h]

1350 / 2700 2250 / 4500

1350 / 2700 2250 / 4500

Temperature rise of passing
air at full output

[°C]

-

-

27 / 13

27 / 13

Sound level

[dB(A)]

44 / 62

45 / 63

44 / 62

45 / 63

Weight

[kg]

44

71

54

86

Length

[mm]

1000

1670

1000

1670

Protection class

IP 24

IP 24

IP 24

IP 24

Accessories

Type

Measures (BxLxD)

Air flow selector (4-step)*

1

ACR 304

80x100x90 mm

Air flow selector high/low *

1

ACR 3042

150x200x105 mm

Air flow regulator (stepless), AC 401-402 *

2

2221AG

85x170x63 mm

Output selector    (0 – 

1

/

2

 – 

1

/

1)

EV 300

80x100x90 mm

Position limit switch

AGB 304

2-step thermostat

KRT 2800

60x165x60 mm

Mounting plate for vertical mounting

AVMP 300

Adaption set for ceiling mounted sliding doors

AXT401

Adaption set for ceiling mounted sliding doors

AXT402

False ceiling grille (1192 x 192)

22003

False ceiling grille (1515 x 192)

22004

*

Regulation for a max of 3 units

*

Regulation for a max of 1 units (2xAC401)

23

GB

Complete technical documentation is
available.

EC Declaration of Conformity

Defined by the EC Electromagnetic
Compatibility Directive 89/336/EC och
92/31/EC.

The following harmonised standards are in
use:

SS-EN 50 082-1: 1992
SS-EN 60 555-2/3: 1991

Complete technical documentation is
available.

Partille, 19 januari 1998

Mats Careborg
Technical Manager

Summary of Contents for Thermozone AC 400

Page 1: ...Thermozone AC 400 SE 12 8 NO FR 28 24 PL 40 44 IT FI 20 16 GB NL 36 32 RU ES 48 DE ...

Page 2: ...Thermozone AC 400 2 Thermozone AC 400 1000 1665 335 ø 11 ø 20 915 1640 710 400 490 1070 1120 945 770 min 200 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 ...

Page 3: ...Thermozone AC 400 3 Thermozone AC 400 Thermozone AC 400 45 Fig 6 ...

Page 4: ...4 7 5 3 1 2 4 6 8 ACR 304 0 1 3 5 7 1 2 3 4 KS115 1 M AC 401 402 230V M M M M N L PTC 1 2 3 4 5 6 N L N L N L 7 8 9 230V AGB 304 N 2221AG N 2221AG AC 401 402 1 2 3 4 N L 230V AC 401 402 1 2 3 4 N L 230V 9 KS116 1 KS117 1 ...

Page 5: ...1 2 3 4 5 6 N L 230V AGB 304 34 35 36 37 38 33 ACR 3042 32 1 2 3 4 31 AC 401 402 4 5 6 9 9 KS109 1 5 7 5 3 1 2 4 6 8 ACR 304 Relay Relay if Thermozone I 6A motors AGB 304 AC 401 402 1 2 3 4 5 6 N L AC 401 402 4 5 6 9 9 230V KS110 1 ...

Page 6: ...15 10 AC 412 418 4 5 6 3 2 1L L L 400V 3 230V 3 12131415 10 230V KS113 1 1 2 3 2 3 1 Hi Lo KRT 2800 16A 230V 10A 400V 400V 3 230V 3 6 7 5 3 1 2 4 6 8 ACR 304 0 1 3 5 7 1 2 3 4 3 2 1 400V 3 L L L K2 K3 230 V 3 K1 10111213 15 14 400V 3 230V 3 5 1 2 6 EV 300 6 2 M AC 412 418 400V 3 N 230V 3 M M M M N L PTC 1 2 3 4 5 6 N L N L N L 7 8 9 230V 2 3 2 3 1 Hi Lo KRT 2800 16A 230V 10A 400V KS112 1 ...

Page 7: ...418 4 5 6 3 2 1L L L 400V 3 230V 3 12131415 10 3 2 1L L L 400V 3 230V 3 12131415 10 5 1 2 6 EV 300 1 2 3 2 3 1 Hi Lo KRT 2800 16A 230V 10A 400V AGB 304 34 35 36 37 38 33 ACR 3042 32 1 2 3 4 31 AC 412 418 4 5 6 3 2 1L L L 12131415 10 400V 3 230V 3 KS119 1 MA120 1 ...

Page 8: ...ckets securely to the wall or other suitable structure Attach the air curtain to the brackets Fig 1 The units are secured with M10 screws in the centre hole of each bracket and in one of the notches thus allowing the whole unit to be turned and the angle of the air stream to be adjusted Observe the minimum distances given in fig 3 and also that the units may not be mounted directly below a power o...

Page 9: ...e with a cable type S05VV U A05VV R or similar On the upper side of the unit there are knock outs 2 pcs ø 29 and 4 pcs ø 23 The cable glands used must guarantee the protection class requirements Type Power Voltage Min area kW V mm2 All control 230V 1 5 AC 412 12 230V 3 10 AC 412 12 400V 3 4 AC 418 18 230V 3 16 AC 418 18 400V 3 10 For the units with electrical heating the power and voltage should b...

Page 10: ...nce other than cleaning when necessary however at least once year Grille impeller and elements are vacuum cleaned or dried clean with a damp cloth Open the inspection hatch to reach elements and impellers GB 22 Safety cut out applies to units with electric heat If the installation is protected by means of a safety cut out which trips when the appliance is connected this may be due to moisture in t...

Page 11: ...lator stepless AC 401 402 2 2221AG 85x170x63 mm Output selector 0 1 2 1 1 EV 300 80x100x90 mm Position limit switch AGB 304 2 step thermostat KRT 2800 60x165x60 mm Mounting plate for vertical mounting AVMP 300 Adaption set for ceiling mounted sliding doors AXT401 Adaption set for ceiling mounted sliding doors AXT402 False ceiling grille 1192 x 192 22003 False ceiling grille 1515 x 192 22004 1 Regu...

Page 12: ...ax 47 0 2 272 38 39 NORWAY e mail mailbox frico no http www frico no France FRICO FRANCE Tel 33 0 4 72 42 99 42 7 rue de la libération Fax 33 0 4 72 42 99 49 F 69 270 Fontaines sur Saone e mail info frico fr FRANCE Russia FRICO representative office in Russia 1 st Golutvinsky per 3 Tel Fax 7 095 238 63 20 Moscow 109180 e mail frico trankm ru RUSSIA Artnr 201210 F89237 00 05 19 For latest updated i...

Reviews: