1. Remove the front plate, and detach the 

electrical connections from the back plate. 

2. Fit the brackets to the wall below the 

coving. See Table B for distance between 
brackets. Allow 15 mm for heater 
expansion.

3. Break off the top spacing part of the 

brackets at the break mark.

4. Fasten the back plate to the brackets.
5. In the connection box on the heater there 

are additional plinths to make it possible to 
further connect to a slave device (ECVTN).

6. Press the two u-nuts into place in the 

bottom flange of the backplate.

7. Re-connect the wiring, be sure to place 

the joints in the connections box. Hook 
the front panel onto the top flange of the 
backplate.

8. Lower the front plate and screw into place 

via the two u-nuts.

Connection

Thermoplus is intended for permanent 
installation.  Thermoplus is equipped with 
extra terminal board sections for further 
current distribution. A junction box is 
therefore not required.  

 
Mounting

Thermoplus among other things is used to 
protect against cold draughts from windows 
and is mounted horizontally above the 
window. Two wall mounting brackets are 
included as standard. Fixtures for ceiling 
mounting are extra, TF1. For minimum 
mounting distance, see p.3. 

Installation and operating instructions

Control 

When using this product as a local space 
heater according to Ecodesign Regulation 
(EU) 2015/1188, it must be supplemented 
with one of the following approved controls. 
Please note that a relaybox RB3 is required 
for 400V~ products.  
• TAP16R, electronic thermostat that 

includes:

 

- Electronic room temperature control plus 

week timer

 

- Room temperature control with open 

window detection 

The product can be controlled in a different 
way, e.g. by an overall control system (BMS), 
but in that case the responsibility lies with 
the installer to ensure that the control system 
is programmed to make the installation meet 
the requirements of Ecodesign Regulation 
(EU) 2015/1188. For ECVTN with a built-
in thermostat, see separate chapter about 
control.  
 

Start-up 

When the unit is used for the first time or 
after a long period of disuse, smoke or odour 
may result from dust or dirt that has collected 
on the element. This is completely normal 
and disappears after a short time. 
  

Maintenance 

 In all electrical heating appliances, small 
clicks can occur due to movement when the 
material expands and contracts with changes 
in temperature. 

General Instructions 

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions. 

 

Application area 

Thermoplus is mounted above windows 
and gives an effecient protection against 
cold draught. The slim shape also makes it 
suitable for heating areas with limited space, 
like for example bathrooms. Thermoplus can 
furthermore be a cost-effective and flexible 
alternative to floor heating.

 

• Thermoplus is available in following 

versions:

 

- - 

Type EC

, for dry rooms. IP20.

 

- - 

Type ECV

, for wet rooms. IP44.

 

- - 

Type ECVTN

, for wet rooms. With a built-

in thermostat (+5 – +37 °C). IP44.

 

- Can also be connected to control over ECV, 

max. total load 10A/3200W.

Summary of Contents for Thermoplus EC Series

Page 1: ... 37 FR 27 NO 17 GB 7 SE 77 IT 67 FI 57 DE 47 ES 87 NL Thermoplus Original instructions 97 PL 107 RU ...

Page 2: ...ling Thermoplus EC Type A mm B mm EC450 1076 600 EC600 1505 900 EC750 1810 1200 EC900 2140 1800 Thermoplus ECV ECVTN Type A mm B mm ECV ECVTN300 870 400 ECV ECVTN550 1505 900 ECV ECVTN700 1810 1200 Ceiling fixtureTF1 Mounting on the wall 135 ...

Page 3: ...3 Thermoplus Flammable material e g curtain mm A 60 B 25 C 90 D 25 E 1800 Minimum mounting distance Flammable material ...

Page 4: ...1 2 3 4 5 6 7 8 4 Thermoplus ...

Page 5: ...ти FI Suurin pintalämpötila 5 SE Vikt GB Weight NO Vekt FR Poids DE Gewicht RU Вес FI Paino Thermoplus EC IP20 Thermoplus ECV IP44 Thermoplus ECVTN IP44 Type Output 1 W Voltage 2 V Amperage 3 A Max surface temp 4 C Weight 6 kg ECVTN30021 300 230V 1 3 180 2 3 ECVTN55021 550 230V 2 4 180 4 6 ECVTN70021 700 230V 3 0 180 5 0 Type Output 1 W Voltage 2 V Amperage 3 A Max surface temp 4 C Weight 6 kg ECV...

Page 6: ...NSOR SENSOR SENSOR LOAD LOAD L N C C TAP16R TAP16R 230V 230V L 1 2 L3 N C EC ECV 230V EC ECV 400V2 RB3 A1A2 L1 L2 L1 L2 L3 L N N T1 T2 T3 L L 1 2 L3 N C Wiring diagram L N 1 2 C ECV 230 V SENSOR SENSOR L N LOAD LOAD TAP16R ECVTN Control by built in thermostat ...

Page 7: ...t that includes Electronic room temperature control plus week timer Room temperature control with open window detection The product can be controlled in a different way e g by an overall control system BMS but in that case the responsibility lies with the installer to ensure that the control system is programmed to make the installation meet the requirements of Ecodesign Regulation EU 2015 1188 Fo...

Page 8: ...ection point Recycling of used products saves earth s resources and reduces global footprint Safety For all installations of electrically heated products should a residual current circuit breaker 300 mA for fire protection be used The unit must not be fully or partially covered with clothing or similar materials as overheating can result in a fire risk E This appliance can be used by children aged...

Page 9: ... on which all settings are made Symbols on the display 1 Day of the week 2 Time and date 3 Selected menu Current temp actual value C 4 Set temp set point C 5 Control F sensor selection ECVTN 6 Shows that a program is running 7 Lock symbol 8 Program 9 Event functions for personal settings ...

Page 10: ...f standby Start the menu Navigate through the options The heat is not being regulated The clock is running and the programming is saved in the memory This is what the display looks like at first start Lock Unlock Or wait 30 secs and exit automatically 4 secs Start up Using the menu Turning off and on Locking the keypad Day ...

Page 11: ...ast two steps to set minutes day month and year The correct day of the week is set automatically Desired temperature Basic settings Lock buttons first The measured temperature is displayed To be able to use all the functions you need to set the time and date first 0 5 C Time and date ...

Page 12: ...gate to LED and select with Navigate between LED L weak light and LED H strong light Confirm with Set display contrast and navigate to CONT Press Select with Confirm with Time and date Navigate between YES NO then confirm with and navigate to SET Press Select with Navigate to DISP and select with Navigate between 12 and 24 hour format Confirm with Turn off DST The calendar switches to DST automati...

Page 13: ...e operation time as a percentage for the last 7 30 365 days Press and navigate to UTIL Delay between turning off and on There is a built in delay in order to avoid unnecessary wear and tear on internal components and to extend the life of the thermostat If you raise the desired temperature so that the thermostat comes on and then lower it shortly afterwards it takes 30 sec before it goes off again...

Page 14: ...reset for home environments Program your own personal settings Tailor the heating to your own needs You have the option of programming time and temperature for four events every day Program personal settings Choose between a whole week or a single day Navigate to the time and temp for the event Confirm and repeat Don t forget to start the program afterwards wakeup out home night Program for office...

Page 15: ...to them when the frost protection program is deactivated Temperature can be set to a level between 5 C and 15 C the factory setting is 10 C Select with The set temperature will flash navigate to the desired temperature Press and navigate to SET Navigate to FP select with Confirm with Important The heating system is a highvoltage system and any faults must therefore be corrected by an authorised el...

Page 16: ... hour format LED Set the strength of the display s backlight AF Turn off and turn on the adaptive function END Exit the menu and return to basic mode RST Reverts to factory settings and deletes all personal settings Sitemap of the menu This is how the menu in the thermostat is structured Here you can quickly see where all the functions and settings are PROG Start stop program UTIL Show connected t...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ain office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se 2018 11 16 HH ...

Reviews: