Thermocassette HP

8

Assembly and operating instructions Thermocassette HP-300/304/305/600/604/605

Area of use

The heating panel is intended for the heating of
rooms requiring free walls. The panel can be used
for complete heating, or as an additional heater
(e.g. over a reception desk or other work place.)
There are two ratings: 300 W(593x593x30 mm)
and 600 W(1193x593x30 mm).
The heating panel provides mainly radiation
heating. This implies that to obtain  the same
experienced temperature it is possible to reduce
the air temperature in the room, which saves
energy.
Because of the low surface temperature, max
100°C, the heating panel is suitable for rooms with
relatively low ceiling height. Thanks to the
location, the panel is protected from any physical
contact or damage. There is no risk of being
burned.

Design

The heating panels are available for 230 and 400
V, which are approved by SEMKO in three
versions:

1 . Ceiling model in standard version (IP20).

See fig. 1.

Intended as lay-in panel fpr exposed grid. The
230 V version have cord and socket, which
ensures simple extended connection (max
2100 W from one wall socket. See fig. 2). The
400 V versions are delivered with a cable
without plug.

2 . Universal model in splash-proof design

(IP54). See fig. 1.

Intended for other methods of mounting (can
also be put in exposed grid). Approved for fire
hazard rooms. The 230 V versions have a cord
(without socket). The 400 V versions are
delivered with a cable without plug.

a .

Screwed to ceiling with accompanying
mounting brackets.

b.

Hanging in wire (with accessory
”Wire mounting kit” 74 701 90).

3 . Universal model in flush-proof design (IP55).

See fig. 1.

Identical with 2, but with better protection
against water. Delivered with cable without
plug.

Mounting

Integrated in ceiling (put in exposed grid).
See fig. 3.

1 . Lateral distance to wall shall be at least

50 mm.

2 . Installation, which is to be preceded by an all-

pole switch, must be carried out by an
authorized electrician (not applicable to
versions with a cord).

3 . Place the cassette in the required ceiling

square. Minimum design height ”H” for
dismounting, T-profile 32x15: 150 mm,
T-profile 38x24: 200 mm.
NOTE! Avoid fixing vertical bars in the T-profile
where a heating panel is to be installed.
The panel fills out the whole square.

4 . Connect the panel.

Bracket mounting. See fig. 4.

1 . Mounting height above floor shall be at least

1.8 m, and lateral distance to wall at least 50
mm. When mounting in gypsum board, make
sure that the mounting brackets are anchored in
the beam behind. During long-term high
temperatures the strength of the board is
reduced.

2 . Installation, which is to be preceded by an all-

pole switch, must be carried out by an
authorized electrician (not applicable to
versions with a cord).

3 . Measure, drill and screw the two loose brackets

to the ceiling. Do not tighten the screws yet. It is
important that the holes come at right angles,
cross measure.

4 . Hook the panel brackets to the ones on the

ceiling (only the side nearest to the connection
box).  Allow panel to hang vertical.

5 . Connect the panel.
6 . Swing up the panel, and adjust the lateral

position of the ceiling mounted brackets.

7 . Swing down the panel and tighten the screws in

the ceiling.

8 . Swing up the panel again and hook the panel

bracket ends in the ceiling brackets. NOTE!
Make sure that the brackets do not become
unhooked at the other end.

9 . Secure the panel with a screw (enclosed on

delivery) at each hanging point.

Summary of Contents for Thermocassette HP300

Page 1: ...Thermocassette HP SE 4 GB 8 NO 6 DE 10 ...

Page 2: ...Thermocassette HP 2 ...

Page 3: ...Thermocassette HP 3 ...

Page 4: ...f design IP55 See fig 1 Identical with 2 but with better protection against water Delivered with cable without plug Mounting Integrated in ceiling put in exposed grid See fig 3 1 Lateral distance to wall shall be at least 50 mm 2 Installation which is to be preceded by an all pole switch must be carried out by an authorized electrician not applicable to versions with a cord 3 Place the cassette in...

Page 5: ... screws 6 Connect the panel Technical Data Ceiling model standard version IP20 T yp HP 300 HP 300 HP 600 HP 600 Power W 300 300 600 600 Voltage V 230 400 230 400 Current A 1 30 0 75 2 61 1 50 Weight kg 5 4 5 3 10 3 10 2 Order nr 84 030 21 84 030 31 84 060 21 84 060 31 Universal model waterproof version IP54 T yp HP 304 HP 304 HP 604 HP 604 Power W 300 300 600 600 Voltage V 230 400 230 400 Current ...

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...4 Partille 15 December 1995 Mats Careborg Teknisk Chef Declaration of Conformity We Frico AB Box 102 S 433 22 Partille under own responsibility hereby declare that the following product s Room heaters Ceiling cassettes Type HP 300 HP 304 HP 344 and HP 305 HP 600 HP 604 HP 644 and HP 605 which is are covered by this declaration of conformity comply with the EC Electromagnetic Compatibility EMC Dire...

Page 13: ... 1910 N 0614 Oslo e mail mailbox frico no NORWAY http www frico no France FRICO FRANCE Tel 33 0 4 72 42 99 42 7 rue de la libération Fax 33 0 4 72 42 99 49 F 69 270 Fontaines sur Saone e mail info frico fr FRANCE Russia FRICO representative office in Russia 1 st Golutvinsky per 3 Tel 7 095 238 63 20 Moscow109180 Fax 7 095 238 64 20 RUSSIA e mail frico orc ru For latetest updated information see ww...

Reviews: