General Instructions

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions.

Area of use

The heating panel is intended for the heating 
of rooms requiring free walls. The panel 
can be used for complete heating, or as an 
additional heater (e.g. over a reception desk 
or other work place).

There are two ratings: 300 W and 600 W.
The heating panel provides mainly radiation 

heating. This implies that to obtain  the 
same experienced temperature it is possible 
to reduce the air temperature in the room, 
which saves energy.

Because of the low surface temperature, 

max 100°C, the heating panel is suitable 
for rooms with relatively low ceiling height. 
Thanks to the location, the panel is protected 
from any physical contact or damage. There 
is no risk of being burned.

Design

1.  Ceiling model: Intended as lay-in panel for 

exposed grid. With cord, socket and plug, 
which ensures simple extended connection 
(max 2100 W from one wall socket).

2.  Universal model in flush-proof design 

(IP55): With better protection against 
water. Delivered with cable without plug 
and brackets.

One or more units have to be connected to 
power line with a differential circuit breaker 
rated at 30 mA. The cable section has to be at 
least 1,5 mm

2

.

Units with cable and plug can be inter-

connected using the sockets on the back of  
the heaters. The maximum power in inter-
connection is 2100 W.

If the units are to be extra insulated, then 

this insulation must not exceed a value  of 
R=5 m

2

K/W.

Mounting

Integrated in ceiling (put in exposed grid)
See fig. 2
1.  Lateral distance to wall shall be at least 
 

50 mm.

2.  The heater(s) should only be wired by a 

competent electrician, and in accordance 
with existing national regulations. The 
appliance should be preceded by an all 
pole switch in accordance with existing 
regulations (not applicable to versions with 
a cord and plug).

3.  Place the cassette in the required ceiling  

square. Minimum design height ”H” for  
dismounting, T-profile 32x15: 150 mm,

 

T-profile 38x24: 200 mm. NOTE! Avoid 
fixing vertical bars in the T-profile where a 
heating panel is to be installed. The panel 
fills out the whole square.

4.  Connect the panel.
5.  The second last page in this mounting 

instruction is to be filled out and fixed 
adjacent to the distribution board and it 
has to contain (drawing) the locations of 
the heating units.

Bracket mounting
See fig. 3
1.  Mounting height above floor shall be at 

least 1,8 m, and lateral distance to wall at 
least 50 mm. When mounting in gypsum 
board, make sure that the mounting 
brackets are anchored in the beam behind. 
During long-term high temperatures the 
strength of the board is reduced.

2.  The heater(s) should only be wired by a 

competent electrician, and in accordance 
with existing national regulations. The 
appliance should be preceded by an all 

Mounting and assembly instruction

Summary of Contents for Thermocassette HP Series

Page 1: ...Thermocassette HP 6 14 10 12 8 GB FR NO DE SE 16 FI 18 RU ...

Page 2: ...te HP 2 HP605 HP305 False ceiling HP300 600 Min distance mm Ceiling 80 Wall long side of the unit 50 Wall short side of the unit 50 Obstacle 500 Floor 1800 Fig 1 Minimum mounting distance Minimum mounting distance ...

Page 3: ...Thermocassette HP 3 Mounting Min 1 5 mm Max 2100W Fig 3 A B C D E Fig 1 Fig 2 ...

Page 4: ... IP55 jet proof design CE compliant Complies with the requirements for flammable areas according to SEMKO 111FF 1 SE Effekt GB Output NO Effekt FR Puissance DE Heizleistung RU Мощность FI Lämmitysteho 2 SE Spänning GB Voltage NO Spenning FR Tension DE Spannung RU Напряжение FI Jännite 3 SE Ström GB Amperage NO Strøm FR Intensité DE Stromstärke RU Ток FI Virta 4 SE Maximal yttemperatur GB Max surfa...

Page 5: ...ring diagrams HP L N HP K 1 2 U 3 4 U K G G L N 230V ERP HP L N HP L N HP L N HP L N HP P 230V N Thermostat Control by thermostat Output control Internal wiring diagram ERP T10S TK10S 230V HP300 HP600 HP300 HP600 L N HP 230V ...

Page 6: ...he cable section has to be at least 1 5 mm2 Units with cable and plug can be inter connected using the sockets on the back of the heaters The maximum power in inter connection is 2100 W If the units are to be extra insulated then this insulation must not exceed a value of R 5 m2 K W Mounting Integrated in ceiling put in exposed grid See fig 2 1 Lateral distance to wall shall be at least 50 mm 2 Th...

Page 7: ...ts NOTE Make sure that the brackets do not become unhooked at the other end 9 Secure the panel with a screw enclosed on delivery at each hanging point fig 3E 10 The second last page in this mounting instruction is to be filled out and fixed adjacent to the distribution board and it has to contain drawing the locations of the heating units Replacement of cable for HP305 or HP605 1 Because of limita...

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ...d OBS do not restrict the thermal emission of the heated ceiling do not affix materials other than those recommended do not insert nails or screws HP300 300W 220 240V HP305 300W 220 240V HP600 600W 220 240V HP605 600W 220 240V Drawing of the installation ...

Page 12: ...100601 HH Main office Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se ...

Reviews: