EN

Maintenance 

The power supply to the unit must be 

disconnected during all service, repair and 

maintenance work. Wait until the unit is cold.  

The unit has no moving parts so the 

maintenance requirement is small, but it must 

be kept clean and free from dust and dirt. If 

the reflector is not clean the thermal radiation 

from the unit will decrease and the heater will 

become hotter. A large amount of dirt can 

cause overheating. 

The surface of the reflector is sensitive and 

must be cleaned with care. If the reflector 

is dirty it must be cleaned or replaced by a 

specialist.  

To clean the casing, wipe it with a soft, dry 

cloth. If it is very dirty, use a slightly damp 

cloth and, if necessary, a mild detergent. Wipe 

afterwards with a dry cloth to remove moisture.   

 

Residual current circuit breaker

When the installation is protected by means of 

a residual current circuit breaker, which trips 

when the appliance is connected, this may be 

due to moisture in the heating element. When 

an appliance containing a heater element has 

not been used for a long period or stored in 

a damp environment, moisture can enter the 

element. 

This should not be seen as a fault, but is 

simply rectified by connecting the appliance to 

the main supply via a socket without a safety 

cut-out so that the moisture can be eliminated 

from the element. The drying time can vary 

from a few hours to a few days. As a preventive 

measure, the unit should occasionally be run 

for a short time when it is not being used for 

extended periods of time. 

 

Packaging

Packaging materials are chosen with 

consideration to the environment and are 

therefore recyclable.  

 

Handling of product at end of working 

life

This product may contain substances necessary 

for the functionality of the product but 

Replacing the lamp and silicon sealing  

The heat lamp is of the highest quality and 

unless it is subjected to mechanical strains in 

the form of vibrations and impact it will last for 

a long time. The service life is dependent on 

the ambient temperature and how the heater 

is installed. When the heater is installed freely 

and outdoors the temperature will be low and 

the life of the lamp can be expected to be in the 

region of 5000 hours.  

When replacing the lamp, the silicone sealing 

connected to the lamp must also be replaced, 

it should be replaced beforehand if there are 

signs of aging.  

The lamp must be replaced by an installer or 

other skilled person.  

 

1. 

Disconnect the power supply. 

2. Wait until the unit is cold.  

3. 

Remove the screws (6x) that holds the two 

plastic gables. 

4. 

Remove the plastic gables.  

5. 

Disconnect white cables (no other cables 

should be disconnected).  

6. 

Remove the screw for the earth connection 

from the reflector.  

7. 

Apply some denatured alcohol with a cloth on 

the lamp beside the silicone sealing before 

removing the lamp.  

8. 

Remove the lamp by pushing it out of one 

of the silicone sealings until one end is 

free, then it can be pulled out of the second 

sealing.  

9. 

Replace the silicone sealings to new ones 

(make sure that the sealing is properly 

assembled). 

10. 

Apply some denatured alcohol on the new 

lamp (at least 10 cm in from each end) before 

assembly. 

battery life.   

• 

Always use the same type of batteries when 

changing them.  

•  The heater can still be used if the remote 

control is missing or not working.  

• 

The remote control may not function should 

there be a loss of signal between the remote 

control and the heater.  

 

Start-up 

When the unit is used for the first time or after 

a long period of non-use, smoke or an odour 

may result from dust or dirt which has collected 

on the element. This is completely normal and 

disappears after a short time. 

 

11. 

Assemble the new lamp and make sure that 

the silicone sealing is tight around the lamp 

ends. 

12. Reassemble the rest of the unit again 

and make sure that no cables are pinched 

between gables and inner gable. 

Summary of Contents for Infraflex

Page 1: ...Infraflex Original instructions 7 EN 10 SE 13 NO 16 FR 19 DE 22 NL 25 ES 28 IT 31 PL 34 RU 37 FI DK 40 ...

Page 2: ...le DE Mindestabstand Entflammbares Material NL Minimale afstand Brandbaar materiaal ES Distancias mínimas Material inflamable IT Distanze minime Materiali infiammabili PL Minimalne odległości Materiał łatwopalny RU Минимальные расстояния при установке Легковоспламеняемые материалы FI Minimietäisyydet Tulenarka materiaali DK Minimumsafstande Brændbart materiale INF12 18 124 83 721 826 ...

Page 3: ...zen NL De stralers moeten voor een gelijkmatige verwarming vanuit minimaal twee richtingen werken ES Para garantizar una calefacción uniforme deben colocarse de modo que el calor llegue desde al menos dos direcciones IT Per avere un riscaldamento uniforme il calore deve provenire da almeno due direzioni PL Aby zapewnić równomierne ogrzewanie ciepło powinno pochodzić co najmniej z dwóch kierunków R...

Page 4: ...Infraflex 4 Fig 4 Fig 5 Fig 3 2x 2x 2x 2x Fig 2 2x ...

Page 5: ...Infraflex 5 Fig 6 INFHA05 Fig 7 INFHA05 Fig 8 INFP A C B A B C ...

Page 6: ...rage SE Ström NO Strøm FR Intensité DE Stromstärke NL Stroomsterkte ES Intensidad IT Corrente PL Natężenie RU Ток FI Virta DK Strømstyrke EN Max filament temperature SE Maximal glödtrådstemperatur NO Maksimal glødetrådtemperatur FR Température max du filament DE Max Heizfadentemperatur NL Max gloeidraadtemperatuur ES Temperatura máx del filamento IT Temperatura max filamento PL Maks temperatura ża...

Page 7: ...eved if the heat is distributed from at least two directions Fig 1 A rule of thumb for infrared heaters is that 600 800 W m increases the experienced temperature by about 10 C The output demand can be reduced if the area to be heated is protected If the area only has a roof at least 800 W m should be installed 600 W m is sufficient if the area has three walls For enclosed areas the output demand m...

Page 8: ...s of the highest quality and unless it is subjected to mechanical strains in the form of vibrations and impact it will last for a long time The service life is dependent on the ambient temperature and how the heater is installed When the heater is installed freely and outdoors the temperature will be low and the life of the lamp can be expected to be in the region of 5000 hours When replacing the ...

Page 9: ...nt area This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made ...

Page 10: ...ce Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 05 13 HH CH ...