General Instructions

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions.

Application 

Infrared halogen IH is the perfect choice 
for exposed outdoor environments where 
design is important, for example, balconies, 
pavement cafés, etc. IH can also be used 
as local heating in large premises such as 
churches, industries and warehouses. IH is 
available in two different designs. IHW gives 
a comfortable heat in the occupied zone from 
close range and also wider heat distribution. 
IHF has more direct heat distribution and is 
designed to be installed higher up. Infrared 
halogen IH is energy efficient, as it is only 
used when there is a heating requirement.  
Protection class: IPX4

Positioning   

The heaters must be placed so that they 
enclose the area to be heated, see fig. 3. The 
normal assembly height is 2–3 metres above 
the ground/floor. A rule of thumb for infrared 
halogen is that 600–800 W/m² increases the 
experienced temperature by about 10 °C. The 
output demand can be reduced if the area to 
be heated is protected. If the area only has a 
roof, at least 800 W/m² should be installed. 
600 W/m² is sufficient if the area has three 
walls. For enclosed areas, the output demand 
must be calculated. Optimum comfort is 
achieved if the heat is distributed from at 
least two directions. 

We recommend an installation height of 

1.8 - 2.5 m for IHW which has wide heat 
distribution and an installation height of 2.3 
- 3.5 m for IHF which gives a focused heat 
distribution.

Mounting 

IH is mounted on the wall using the bracket. 
The heater can also be mounted on e.g. 
a parasol or a post, a suitable U-bolt (not 
included) is used for this together with the 
supplied console. Other alternatives are 
possible, e.g. suspended from the ceiling.

The heater must be mounted in a horizontal 

position in order to keep the lamp horizontal. 

The heater can be directed straight out from 

the wall or angled up to 45°. 

For minimum measurements, see fig. 4.

1. Secure the bracket on the wall, see fig. 2. 

Note that the wall bracket must not only be 
fitted with the screws in the keyhole slots.

2. Remove the screws fixed to the unit's 

attachment on delivery.

3. Hook the attachment on the bracket.
4. Lock in position with the screws.

Note that the unit must not be placed directly 
under the permanent wall socket.

Electrical installation

IH is equipped with a 0.9 metre cord with 
plug for connection to an earthed outlet 
socket. 

The connection cord must not rest against 

the unit as the surface becomes hot or can 
be hit by thermal radiation. Contact an 
electrician if the cord needs to be changed. 
Note that due to the high temperatures in 
the heater, a cord of the type H05 SS-F 3G1 
mmor the like should be used.

As the halogen lamp has a high starting 

current the wall socket should be fuse 
protected by a slow burn fuse. 

In the event of uncertainty contact an 

electrician.

Assembly and operating instructions

Summary of Contents for IHF10

Page 1: ...IH 6 SE 8 GB 20 DE...

Page 2: ...tioning Fig 2 Minimum mounting distance Fig 1 The heaters should heat from at least two directions for even heating Type IH mm A 200 B 1000 C 1800 B A C 46 5 60 115 24 8 17 5 25 5 35 Fig 3 Bracket mea...

Page 3: ...IH 3 1 3 3 4 5 2 1 Replacing the halogen lamp Fig 5 500 169 160 0 9 m 77 147 Fig 4...

Page 4: ...IH 4 Wiring diagrams IH Timer control Timer control with contactor N IH 1 2 3 CBT L N L N IH L N IH L 230V Max load 3500W N IH 1 2 3 CBT 230V L N L N IH L N IH L L1 L2 L3 N L N 400V3...

Page 5: ...ght NO Vekt FR Poids RU DE Gewicht PL Waga FI Paino ES Peso Technical specifications Infrared heater IHW with wide heat distribution installation height 1 8 2 5 m 3 Type E nr SE EL nr NO Heat output 1...

Page 6: ...mmer fr n minst tv h ll F r IHW som ger en bred v rmespridning r rekommenderad installationsh jd 1 8 2 5 m och f r IHF som ger en fokuserad v rmespridning r rekommenderad installationsh jd 2 3 3 5 m M...

Page 7: ...paraten vara fr nkopplad Apparaten har inga r rliga delar s kravet p underh ll r litet men den m ste h llas ren fr n damm och smuts Om reflektorn inte r ren kommer v rmestr lningen fr n apparaten att...

Page 8: ...is achieved if the heat is distributed from at least two directions We recommend an installation height of 1 8 2 5 m for IHW which has wide heat distribution and an installation height of 2 3 3 5 m f...

Page 9: ...maintenance work The unit has no moving parts so the maintenance requirement is small but it must be kept clean and free from dust and dirt If the reflector is not clean the thermal radiation from th...