background image

10

Elektra V

Mounting and assembly instruction

Application area

The fan heater is approved for use on ships and 
off-shore applications. Elektra V has reinforced 
electrical insulation, motor and heating elements 
have a construction that absorbs vibrations. For 
both fixed installation and portable use. Elektra 
V is available in 230V~, 400V3~ and 50 Hz and 
440V3~ and 60Hz.

The fan heater should be installed for easy 

maintenance and inspection. For portable use, 
mount a suitable terminal with appropriate 
protection class. The fan heater is tested and 
approved according to the EMC- and SEMKO 
regulations and is CE compliant. Protection class: 
IP44. Approved by DNV, Det norske Veritas. The 
heater is also approved for 440V3~ and 60Hz. 
Casing and heating rods are made of stainless 
steel SS2320.

Operation

The fan is running constantly unless the output 
selector is set in 0 position. The heat output is 
controlled by the built in thermostat (0- +35°C) or 
with an external thermostat (KRT1900). 

The on/off mode, and half or full heat output 

can be controlled with the output selector on the 
unit or with an external control panel (ELSRT/ 
ELSRT4) mounted on the wall for easy access. 
External control box or thermostat are ordered 
separately.

  

Off

 

Only fan

 

Fan + half output

 

Fan + full output

Mounting

Elektra V can be mounted permanently on the 
wall or be used as a portable fan heater. 

Wall mounting

The fan heater must not be placed immediately 
below or in front of a wall socket.
Remove the plastic feet on the brackets.
1.Drill four holes in the wall with a c-c distance 

according to fig. 2 on page 2. 

2.Fit the screws in the upper two holes. 
3.Hang the heater by using the keyholes in the 

bracket and lock with the two lower screws.

 
Note! The minimum distances according to fig. 1 
on page 2.

Portable use

1.Loosen the three screws with washers from the 

motor, see Fig. 7 page 3.

2.Loosen the screws on the bracket (the bracket 

is fitted on the casing).

3.Then loosen the two screws connecting the 

bracket and the support, see Fig. 8 page 3.

4.The support between motor and bracket is 

removed, it is not needed for portable use.

5.Fasten the three screws to the motor, see Fig. 7 

page 3. Note! Don’t forget the washers.

6.Mount the brackets on the fan according to  

Fig. 6 page 3.

Electrical installation

The electrical installation should be carried out 
by a qualified electrician in conformity with 
prevailing regulations. The appliance should be 
preceded by an all-pole switch with at least 3 mm 
breaking gap. 

Use the knock-outs on the back of the appliance 

for installation of the external devices. Cable-
glands used must guarantee the protection class 
requirements.

Overheating 

Note! Opening the heater cover should only be 
done by a qualified installer. 
The heater is equipped with two overheat 
protections, one with manual reset and one with 
automatic reset. If the manual overheat protection 
is released due to overheating, reset as follows:

• Disconnect the power with the fully isolated 

switch.

• Investigate the matter and repair the fault.
• Reset cut-out by opening the lid and pressing 

the red button until a click is heard. 

• Put on the lid and make sure that the screws are 

tightened to ensure full protection. If the fault 
continues or cannot be fixed, please contact a 
qualified technician.

Maintenance

Note! Opening the heater cover should only be 
done by a qualified installer.

Always disconnect the power supply before 

opening the cover or doing any maintenance 
work.

The appliance should be cleaned regularly both 

inside and outside, to prevent overheating and 

GB

Summary of Contents for Elektra V

Page 1: ...Elektra V 8 10 GB 12 NO 18 DE 21 PL 14 FR 23 FI 16 RU SE 31 IT 28 ES 25 NL...

Page 2: ...Elektra V 2 min 500 mm min 300 mm min 300 mm ELV3333 ELV3344 ELV5333 ELV6344 380 300 375 Fig 3 Fig 4 Fig 1 10 419 412 415 415 3 9 16 24 333 375 9 28 c c 277 Fig 2...

Page 3: ...g ELV331 3 0 2 3 230V 9 0 13 3 400 48 21 13 ELV3333 3 0 1 5 3 400V3 4 0 4 6 400 48 21 13 ELV3344 3 6 0 1 8 3 6 440V3 4 4 5 1 400 48 21 13 ELV5323 5 0 2 5 5 230V3 11 1 12 8 700 53 17 13 ELV5333 5 0 2 5...

Page 4: ...witch Schalter Interrupteur Schakelaar 4 Termostat Termostat Termostat Termostaatti Thermostat Thermost Thermostat Thermostaat 5 verhettningsskydd Overophedningsbeskytter Overhetingsvern Ylikuumenemis...

Page 5: ...er Interrupteur Schakelaar 4 Termostat Termostat Termostat Termostaatti Thermostat Thermost Thermostat Thermostaat 5 verhettningsskydd Overophedningsbeskytter Overhetingsvern Ylikuumenemissuoja Overhe...

Page 6: ...4 Termostat Termostat Termostat Termostaatti Thermostat Thermost Thermostat Thermostaat 5 verhettningsskydd Overophedningsbeskytter Overhetingsvern Ylikuumenemissuoja Overheating cut out berhitzungsc...

Page 7: ...Elektra V 7 ELSRT Switch Thermostat ELSRT ELSRT4 ELSRT Switch Thermostat 230V ELC V 3 9 kW ELC V 3 9 kW ELC V 3 9 kW ELC V 3 9 kW ELSRT4 ELSRT4 Thermostat Switch...

Page 8: ...e bracket and lock with the two lower screws Note The minimum distances according to fig 1 on page 2 Portable use 1 Loosen the three screws with washers from the motor see Fig 7 page 3 2 Loosen the sc...

Page 9: ...ck of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the app...

Page 10: ...ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2020 02...

Reviews: