General Instructions 

Read these instructions carefully prior to 

installation and use. Keep this manual for 

future reference.

The product may only be used as set out in 

the assembly and operating instructions. The 

guarantee is only valid should the product be used 

in the manner intended and in accordance with 

the instructions. 

Notes and warnings

•  Warning for appliance with R290 refrigerant 

gas (refer to the rating plate for the type of 

refrigerant gas used).

•  CAUTION ON FIRE

READ THE MANUAL CAREFULLY 

BEFORE USING THE APPLIANCE

R290 refrigerant gas complies 

with European environmental directives.

This appliance contains R290 refrigerant 

gas.

Appliance shall be installed, operated and 

stored in a room with a floor area larger 

than 12 m

2

.

•  For repair and maintenance; see manual 

"Repair and maintenance - units with R290" 

on www.frico.net.

•  To avoid damage, place the unit in an 

upright position for at least 24 hours before 

initiation. 

•  The appliance shall be stored so as to 

prevent mechanical damage from occurring.

•  When the portable air conditioner or 

dehumidifier is turned on, the fan can 

work continuously stable under normal 

conditions to provide the minimum 

air volume of 100 m

3

/h even when 

the compressor is closed due to the 

temperature controller.

•  Do not pierce or burn.

•  Do not perforate any of the components in 

the refrigerant circuit. Refrigerant gas may 

be odourless.

•  The air conditioning (AC) is only suitable 

for indoor use, and is not suitable for other 

applications.

• 

Place the AC in a flat and dry place and keep 

a distance of above 50 cm between the unit 

and the surrounding objects or walls.

•  After the AC is installed, ensure that the 

power plug is intact and firmly plugged into 

the power outlet, and place the power cord 

orderly to prevent someone from being 

tripped or pulling out the plug.

•  Do not put any object into the air inlet and 

outlet of the AC. Keep the air inlet and outlet 

free from obstructions.

•  When drainage pipes are installed, ensure 

that the drainage pipes are properly 

connected, and are not distorted or bended.

•  Use a water trap if the hose is connected to 

the drainage system.

•  While adjusting the upper and lower wind-

guide strips of the air outlet, pluck it with 

hands gently to avoid damaging wind-guide 

strips.

•  When moving the AC, make sure that it is in 

an upright position.

•  The AC should stay away from gasoline, 

flammable gas, stoves and other heat 

sources.

•  Don't disassemble, overhaul and modify 

the AC arbitrarily, otherwise it will cause 

malfunction or even bring harm to 

persons and properties. To avoid danger, 

if failure occurs, ask the manufacturer or 

professionals to repair it.

•  Do not install and use the AC in the 

bathroom or other humid environments.

•  Do not pull the plug to turn off the AC.

•  Do not place cups or other objects on the 

unit to prevent water or other liquids from 

spilling into the AC.

•  Do not use insecticide sprays or other 

flammable substances near the AC.

•  This appliance can be used by children 

aged from 8 years and above and persons 

with reduced physical, sensory or mental 

capabilities or lack of experience and 

knowledge if they have been given 

supervision or instruction concerning use of 

the appliance in a safe way and understand 

the hazards involved. Children shall not 

play with the appliance. Cleaning and user 

maintenance shall not be made by children 

without supervision. 

•  Children of less than 3 years should be kept 

away unless continuously supervised. 

•  Children aged from 3 years and less than 8 

years shall only switch on/off the appliance 

provided that it has been placed or installed 

in its intended normal operating position 

and they have been given supervision or 

instruction concerning use of the appliance 

in a safe way and understand the hazards 

involved. 

•  Children aged from 3 years and less than 8 

years shall not plug in, regulate and clean 

the appliance or perform user maintenance.  

Summary of Contents for Climobile

Page 1: ...Climobile 2 EN 11 SE Original instructions 20 DE ...

Page 2: ...ct into the air inlet and outlet of the AC Keep the air inlet and outlet free from obstructions When drainage pipes are installed ensure that the drainage pipes are properly connected and are not distorted or bended Use a water trap if the hose is connected to the drainage system While adjusting the upper and lower wind guide strips of the air outlet pluck it with hands gently to avoid damaging wi...

Page 3: ...ion and ventilation function Automatic swing hatch in the outlet has automatic air swing function and the outlet can be covered when the AC is turned off to prevent dust from entering the unit LCD screen and LCD remote control to facilitate operation The remote control can be placed on the back of the unit Handles on both sides The hooks to wrap the power cord on the back facilitates users to hang...

Page 4: ...ious components of it 1 3 Install the unit 1 Move the unit with installed vent hose and fittings before the window and the distance between the unit and walls or other objects shall be least 50 cm as shown in fig 4 2 Elongate the vent hose and snap the flat end of the vent hose joints into the elliptical hole of the window cover plate as shown in fig 5 and fig 6 Notes The flat end of the vent hose...

Page 5: ...as follows While setting temperature press up key or down key to select the required temperature not available in ventilation or dehumidification mode Simultaneously press both keys to switch between Celsius C and Fahrenheit F Fan In cooling heating and ventilation mode press the key to select high medium or low fan speed operation In dehumidification mode low fan speed operation is automatically ...

Page 6: ...ration 3 2 Overflow Protection Function When water in the water pan exceeds the warning level the AC will automatically sound an alarm and the LDC screen will show FL At this point you need to move the drainage pipe connecting the AC or the water outlet to a sewer or other drainage area to empty the water details see Drainage Instructions at the end of this chapter After the water is emptied the A...

Page 7: ...n be tilted slightly backwards If the container cannot hold all the water before it is full block the water outlet with the water plug as soon as possible to prevent water from flowing to the floor or the carpet 4 When the water is emptied insert the water plug and tighten the drainage cover Notes Restart the AC after the water plug and drainage cover are installed otherwise condensate water will ...

Page 8: ...ng clean 2 2 Clean the lower filter screen frame Hold the handle of the CON filter screen frame and pull it outward gently to remove it Put the CON filter screen into warm water with neutral detergent about 40 C 104 F and dry it in the shade after rinsing clean Storage Unscrew the drainage cover unplug the water plug and discharge the water in the water pan into other water containers or directly ...

Page 9: ... of heat Close doors and windows and add new air conditioning The filter screen is dirty Clean or replace the filter screen The air does not pass freely through the unit Make sure the air inlet and outlet are not obstructed Big noise The unit is not placed on a flat surface Put the unit on a flat and hard surface to reduce noise The compressor does not work Overheat protection is activated Wait fo...

Page 10: ...ment and are therefore recyclable Handling of product at end of working life This product may contain substances necessary for the functionality of the product but potentially dangerous for the environment The product should not be disposed of mixed with general household waste but delivered to a designated collection point for environmental recycling Please contact the local authority for further...

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ... 23 HH CH Main office Frico AB Tel 46 31 336 86 00 Industrivägen 41 SE 433 61 Sävedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net ...

Reviews: