Page 1: ...PA2200C 20 SE 27 EN Original instructions 33 NO 40 DE 48 ES 55 FR 63 IT 71 NL 79 PL 86 RU 92 FI...

Page 2: ...setzung der verwendetenTexte in englischer Sprache siehe die entsprechenden Sprachseiten DE Las p ginas introductorias contienen b sicamente im genes Consulte la traducci n de los textos en ingl s que...

Page 3: ...345 min 500 min 500 min 500 157 157 157 90 5 10 20 40 22 210 165 184 1026 1536 2026 1050 1560 2050 Cu 15 53 71 40 min 500 min 500 157 157 Cu 15 PA2200C 3 PA2200C Gland Knock out Knock out Knock out Gl...

Page 4: ...PA2200C 4 Fig 3 Open the unit A B C TX20...

Page 5: ...30 mm 60 mm min 60 PA2200C 5 Fig 4 Fig 5 Minimum distance...

Page 6: ...min 500 mm 20 35 75 210 33 8 3x 5 10 162 PA2200C 6 Fig 6 Mounting with wall brackets Mounting with wall brackets A B C PA2210 2 pcs PA2215 2 pcs PA2220 3 pcs D...

Page 7: ...25 DN25 VLSP32 DN32 VOT15 DN15 VOT20 DN20 VOT25 DN25 PA2200C 7 PA2DR PA34TR15 PA2210C PA2215C 1 m PA34TR20 PA2220C 1 m PA2P15 PA2210C PA2215C 1 m PA2P20 PA2220C 1 m PA2PF15 PA2210C PA2215C PA2PF20 PA2...

Page 8: ...050 35 2 Water heat PA2200C W 3 Electrical heat PA2200C E 1 Ambient no heat PA2200C A 1 Lowest highest airflow of totally 3 fan steps 2 Sound power LWA measurements according to ISO 27327 2 2014 Insta...

Page 9: ...PA2210CA PA2215CA PA2220CA Right motor Left motor Only 2 m version PA2200C 9 PA2210CA PA2215CA PA2220CA...

Page 10: ...2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR M Blue Black Brown C Over heat cut out C C1 L2 PE L1 L N L3 400V 3N L2 PE L1 L N L3 230V 2210CE03 2210CE05 PA2210CE03 PA2210CE05 C3 Run...

Page 11: ...H1H2 N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR M Blue Black Brown C Lo Mid Run Over heat cut out C C1 L2 PE L1 L N L3 230V 2210CE051 PA2210CE051 PA2200...

Page 12: ...R INTERNAL SENSOR IR C2 Over heat cut out C C1 L2 PE L1 L N L3 400V 3N Over heat C cut out PA2215CE08 PA2220CE10 M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left motor On...

Page 13: ...out C C1 C1 low power C2 high power L2 PE L1 L N L3 400V 3N Over heat C cut out PA2210CE08 PA2215CE12 PA2220CE16 M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left motor On...

Page 14: ...L PE 0 10V 0 10V HEAT ALARM WATER INTERNAL SENSOR IR PA2210CW PA2215CW PA2220CW M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left motor Only 2 m version C3 Run C2 Lo C1 M...

Page 15: ...M WATER INTERNAL SENSOR IR C2 Over heat cut out C C1 L2 PE L1 L N L3 400V 3N Over heat C cut out 230V 3 400V 3 a1 a2 b2 c2 c1 b1 a1 a2 b2 c2 c1 b1 L2 PE L1 L N L3 230V 3 PA2210CE05YD PA2215CE08YD M Bl...

Page 16: ...A2220CE10YD L2 PE L1 L3 400V3 L2 PE L1 L3 230V3 C4 C3 230V 3 400V 3 a1 a2 b2 c2 c1 b1 a1 a2 b2 c2 c1 b1 M Blue Black Brown C Right motor M Blue Black Brown C C3 Run C2 Lo C1 Mid Left motor C3 Run C2 L...

Page 17: ...PAMLK C NC NO Motor alarm pot free contact M Blue Black Brown C Lo Mid Run Left motor Only 2 m version 5A x 3 5A 16A N H1H2 N 1 On Off F1 F2 F3 on off 2 N L PE N L PE 0 10V 0 10V HEAT ALARM WATER INTE...

Page 18: ...53 1 0 07 2 9 13 6 40 2 0 17 13 5 min 1000 5 8 43 3 0 03 0 7 9 5 45 9 0 12 7 0 PA2220CW max 2400 13 9 55 4 0 10 2 7 17 7 39 7 0 22 11 1 min 1400 8 1 46 2 0 05 0 7 12 8 45 0 0 16 6 3 Supply water temp...

Page 19: ...1 6 See www frico se for additional calculations 1 Recommended outlet air temperature for good comfort and optimized output 2 Nominal output at given supply and return water temperature Supply water...

Page 20: ...lly heated units is 1800 mm For other minimum distances see fig 4 Mounting with wall brackets fig 6 1 Mount the brackets on the wall see fig 6A and dimension drawing fig 1 If the wall is uneven the br...

Page 21: ...pipes and subsequent water leakage during connection to water supply pipe work Dimensioning of external wiring shall comply with applicable regulations and local deviations may occur Minimum area Cont...

Page 22: ...rtain effect and the heat emission from the device How often depends on local circumstances A clogged filter is not a risk but the appliance function can fail 1 Disconnect the power supply 2 The front...

Page 23: ...ating also check the fol lowing Power supply to electric heater coil check fuses and circuit breaker if any That the overheat protection for the motors has not been deployed For units with water coil...

Page 24: ...etting dip switches Unit with water heating Dip switch 3 is used for PA2DR optional OFF Actuator SD230 remove the quick connector Black Brown Blue External on off Eg time switch External potential fre...

Page 25: ...minutes to vent out the heat if the temperature rises above 50 C again during the following 5 minutes overheating alarm is deployed The red LEDs flash and all the buttons are locked 1 Disconnect the e...