5.
CLEANING AND MAINTENANCE
WARNING
Never use a water hose for cleaning.
Water can seep into the unit through the
ventilation holes of the unit
.
Mains power must be switched off during cleaning or maintenance and when
replacing parts.
Because of hygiene aspects
and optimum condition
of the unit it is of utmost
importance to keep a daily cleaning pattern from first use onwards
.
5.1
Maintenance schedule
Item
Action
Frequency
Inside
•
Clean, see section 5.2.
Daily
Outside
•
Clean, see section 5.3.
•
Use Stainless Steel cleaning spray to remove
stains, and restoring the gloss.
Weekly
Glass panes
•
Clean front, side and back glass panes.
Weekly
Humidifier
•
Clean, refer to humidifier manual.
Weekly
Interior bottom
•
Clean, see section 5.4.
Monthly
Condenser
•
Clean, see section 0.
Monthly
5.2
Daily Cleaning
•
Clean the inside of the unit with hot water and a suitable cleaner.
•
After cleaning wipe the inside with a clean wet cloth. Be sure that the detergent is removed
properly
.
•
Do not use excess water in case the cold unit is fitted with an evaporation tray as it could
overflow.