6.
MALFUNCTIONS AND SERVICE
Before you contact your supplier/dealer in case of a malfunction, there are some items you can
check yourself:
Is the power supply working properly? Check fuses and differential switch.
Has the timer clock been properly set?
Item
Malfunction
Possible action
Element
The heating element
colours red
Remove the plug from the outlet.
Have the fault corrected.
Fan
The fan does not rotate
Remove the plug from the outlet.
Open the door.
Remove the rear panel (see section 5.3)
and check if the fan can rotate freely.
Oven
The oven does not
become hot
Open and close the door.
Check the fuses and the earth leakage
switch in the meter cupboard.
Steam
(with BC - P only)
No steam injection
Check the water connection.
Door
Does not close
Place the oven in a horizontal position
such that the closing pins fall into the
door hinges.
Check if the door switch is not positioned
too far to the outside.
Bottom
(with BC - P only)
The bottom becomes
wet
Reduce the number of steam pulses.
Mains cord
Damaged
Replace, see section 6.1
6.1
Replace the mains cord
WARNING
Hazardous electrical voltage.
If the mains cord is damaged, it must be replaced by the manufacturer, his service agent or a
similarly qualified person in order to avoid hazards.