3.7. Access Control
Login to the website and go to Phone - Time/Lang, to configure
time and language
3.7.1. Relay
Go to
Intercom
-
Relay
to configure relay settings.
There are three terminals of relay: NO, NC and COM. NO stands
for normally open contact. NC stands for normally closed contact.
Relay ID:
FE-IPDS-28A supports three relays. Users can configure
them respectively.
Relay Type:
Default state means NC and COM are normally
closed, while Invert state means NC and COM are normally
opened.
Relay Delay:
To configure the duration of opened relay. Over the
value, the relay would be closed again.
Relay Status:
While the relay is triggered, the statues will be
switched. When COM connects to NC, the status is low.
Figure 3.7.1 Relay