1.

 

Getting Started 

 

In this installation guide, we will explain how to install and configure Freund IP-INTEGRA Access 
Control Units and Freund Access Control Readers. 

 

This Installation Guide explains how to install and configure FREUND IP-INTEGRA Access Control 
Units and FREUND ACC-Readers.  

Please  read  this  User  Manual  carefully  before  using  the  product.  Follow  all  instructions  and 
recommendations included herein.  

Any use of the product that is in contradiction with the instructions provided herein may result in 
malfunction, damage, or destruction of the product.  

The manufacturer shall not be liable and responsible for any damage incurred as a result of a use of 
the  product  other  than  that  included  herein,  namely  undue  application  and  disobedience  of  the 
recommendations and warnings in contradiction herewith.  

Any use or connection of the product other than those included herein shall be considered undue 
and the manufacturer shall not be liable for any consequences arisen as a result of such misconduct.  

Moreover, the manufacturer shall not be liable for any damage or destruction of the product incurred 
as a result of misplacement, incompetent installation and/or undue operation and use of the product 
in contradiction herewith.  

The  manufacturer  assumes  no  responsibility  for  any  malfunction,  damage  or  destruction  of  the 
product caused by incompetent replacement of parts or due to the use of reproduction parts or 
components.  

The manufacturer shall not be liable and responsible for any loss or damage incurred as a result of 
a natural disaster or any other unfavorable natural condition.  

The manufacturer shall not be held liable for any damage of the product arising during the shipping 
thereof.  

The manufacturer shall not make any warrant regarding data loss or damage.  

The manufacturer shall not be liable and responsible for any direct or indirect damage incurred as 
a result of a use of the product in contradiction herewith or a failure of the product due to a use in 
contradiction herewith.  

All applicable legal regulations concerning the product installation and use as well as provisions of 
technical standards on electric installations must be obeyed.  

The manufacturer shall not be liable and responsible for damage or destruction of the product or 
damage incurred by the consumer in case the product is used and handled contrary to the said 
regulations and provisions.  

 

Summary of Contents for FE-ACC-INT2D

Page 1: ...ND ELEKTRONIKA d o o International Burch University Francuske revolucije bb 71210 Ilidza Bosnia and Hercegovina www ip integra ba info ip integra com Tel 387 33 922 890 ACCESS CONTROL INSTALLATION MAN...

Page 2: ...ACC INT4D 6 6 Connecting the Access Control module to the power supply and network 9 7 Battery Details 10 8 Connecting the Reader and the door lock to the Access Control module 11 9 Additional notes...

Page 3: ...n of the product incurred as a result of misplacement incompetent installation and or undue operation and use of the product in contradiction herewith The manufacturer assumes no responsibility for an...

Page 4: ...stomer site survey and have determined the following Number of entries needed to configure e g doors gates and or elevator floors Whether you re using existing or new wiring for IP TCP and Reader conn...

Page 5: ...WR FE MF TWR 13 56 MHz RFID card reader 13 56 MHz RFID card reader with keypad License Cluster license USB FE ACC INT2D FE ACC INT4D IP TCP POE based 2 door IP Integra access control module IP TCP PO...

Page 6: ...UAL 6 5 Pin assignment for the FE ACC INT2D and FE ACC INT4D There are two types of control units FE ACC INT2D and FE ACC INT4D INT2D can have two doors connected to it while INT4D can have four doors...

Page 7: ...h PoE switch LAN connecting to network if PoE switch is not available external power supply needs to be connected RSA RSB IN2 GND2 OUT2 IN1 GND1 OUT1 BAT BAT 15V GND RS 485 Battery 12V Power Name Func...

Page 8: ...for second reader SEN Sensor pin BUZZ Buzzer pin for reader LED LED indicator pin for reader 12V Power supply for readers GND GND for readers NC Normally closed pin for relay COM COM for relay NO Nor...

Page 9: ...upplies the module in case there is a power shortage Battery is charged through PoE or external power supply 1 Connecting the battery and PoE where PoE acts as power supply and LAN Red wire from the b...

Page 10: ...7 Battery Details Please refer to the Access controllers and Readers datasheets in order to calculate the suitable battery size related to the Access Control system requirements for power outage Exte...

Page 11: ...e Function Red DC 9 24V Power supply Black GND Power supply Green WD0 Data White WD1 Data Blue LED LED indicators on reader Yellow BUZZER Buzzer on reader Brown RS485 OSDP connection Orange RS485 OSDP...

Page 12: ...from both sides and one door lock 3 Connecting reader from one side and push button from oposite side which is connected to D0B and GND For every type of connection the diode needs to be connected be...

Page 13: ...NUAL 13 Using the OSDP protocol To use the OSDP protocol we need to connect the reader to ACC module as shown in the pictures below In case we are using multiple readers the way to connect them is as...

Page 14: ...FREUND MANUAL 14 On the back side of the reader the DIP switches need to be set up correctly to use the OSDP...

Page 15: ...N PROTECTING YOUR EQUIPMENT AGAINST ELECTRICAL KICKBACK PLEASE FOLLOW THESE INSTRUCTIONS For electric locking devices powered with DC voltage The diode must be installed across the DC powered lock DC...

Reviews: