FreshWater MP1K Installation Manual And Technical Information Download Page 6

 

 

 

 

 

 

 

 
 
MP1K & MP2K Fountain Purifier Installation Guide and Technical Information 

 

 

Fresh Water Filter Co Ltd.  Carlton House, Aylmer Road, Leytonstone, London E11 3AD. 

Tel: +44 (0)20 8558 7495  Fax: +44 (0)20 8556 9270  Email: 

[email protected]

 

www.freshwaterfilter.com

 

MP1K & MP2K Installation Guide & Technical Information (29/05/08) E & OE 

 

Now slowly open the line piercing valve 
tap  and  check  the  entire  installation 
for leaks.  

Check very carefully. 

Once  you  are  happy  that  there  are  no 
leaks, WITH NO CARTRIDGES INSTALLED 
set  the  JP  CERAMICS

®

  outlet  tap  to 

continuous flow mode and flush out the 
line  for  a  few  minutes.    Again,  check 
for  leaks  whilst  the  water  is  on 
continuous flow. 

STEP EIGHT 

8: Inserting the cartridges 

Turn  off  the  water  by  closing  the  line 
piercing  valve  tap  and  relieve  the 
pressure  by  turning  on  the  long  reach 
fountain tap until the flow stops. 

Unscrew  the  housing(s)  from  the 
headworks.  In  the  case  of  the  MP2K 
make  sure  that  the  housing  for  the 
Type A cartridge is kept separate from 
the Type B cartridge. 

Remove  any  protective  wrapping  from 
the  cartridges.    CHECK  THAT  THE 
INTERNAL  SEALING  RING(S)  INSIDE  THE 
HEAD  AND  THE  ‘O’RING  WASHER(S)  ON 
THE  STAINLESS  STEEL  HOUSING(S)  ARE 
CORRECTLY  LOCATED  before  screwing 
the 

housings 

tightly 

onto 

the 

headwork’s. 

STEP NINE 

9: Conditioning 

Before  using  your  JP  CERAMICS,  first 
fill the system with water. 

This is done as follows: 

a)

 

Turn  on  the  water  flow  at  the 

outlet  tap  until  a  continuous  flow  of 
water emerges; - run the whole system 
for  several  minutes  until  the  water 
tastes  good.  For  the  first  few  seconds 
you  may  observe  a  black  water 
condition,  this  is  perfectly  normal  - 
ignore  it  -  and  continue  to  flush  until 
the water runs clean. 

b)  After  carrying  out  the  conditioning 
procedure,  turn  off  the  tap  so  the 
whole  unit  is  fully  under  mains  water 
pressure  and  check  the  unit  very 
carefully  for  leaks.  It  is  important  to 
check  again  after  a  few  hours  in  case 
there is a very slow and small leak. 

 

A  small  saucer  under  the  filter  will 
catch any drips, and will enable you to 
confirm that all is correct. 
 

Section 3 

 

Operating instructions 

1: Routine use

 

Hold the tap lever down to turn on the 
water  flow.  Run  the  water  for  a  few 
seconds before use. 

The  water  flow  rate  should  be  kept  at 
around  1.5  litres  per  minute  at  5  bar 
pressure  for  optimum  performance 
(about 24 seconds to

 

fill a

 

pint bottle).  

The  flow  may  be  reduced  by  partially 
closing  the  control  valve  on  the  line 
piercing assembly. 

During  use,  unwanted  particulate 
material  will  collect  on  the  outside 
surface  of  the  ceramic  membrane  and 
this will reduce the water flow rate.  If 
the line-piercing valve is fully open and 
the  flow  rate  becomes  unacceptably 
low,  this  normally  indicates  that  the 
ceramic  will  need  recleaning  (

see 

Section  Four

).  Since  the  ceramic  is 

easily recleanable  it may be  used over 
and over again.  When, after cleaning, 
the  flow  is  still  not  acceptable  you 
should  replace  your  cartridge.    The 
frequency  of  cleaning  will  depend  on 
how  much  water  you  use  and  the  dirt 
and  particulates  in  the  water.    Please 
note 

that 

the 

latter 

can 

vary 

considerably  from  day  to  day  during 
the  year  and  may  also  depend  on  the 
condition of the pipes in your home. 

Under  normal  conditions,  after  3000 
litres  (over  800  gallons)  of  water  have 
passed  through  your  MP1K  or  six 
months  has  passed,  whichever  is  the 
sooner.    It  is  advisable  to  fit  a  new 
cartridge  unit  to  preserve  optimum 
performance. 

With  the  MP2K  both  cartridges  should 
be  replaced  after  6000  litres  (over 
1000  gallons)  have  passed  through  it, 
or  every  12  months,  whichever  is  the 
sooner. 

Whenever a cartridge is cleaned or 
replaced or the filter housing opened 

for 

inspection, 

please 

check 

carefully to ensure that there are no 
leaks. From time to time, should the 
‘O’ seal become brittle, or break, or 
cause a leak it will need replacing. 

‘O’ seals should be wiped with white 
petroleum  jelly  (Vaseline)  to  help 
lubrication. 

2:  Cleaning  the  cartridge

 

(ceramic only) 

a)

 

Turn  off  the  supply  at  the  line-

piercing valve. 

b)

 

Relieve  the  water  pressure  by 

opening the tap. 

c)

 

Unscrew  the  housings  from  the 

headworks. 

d)

 

Carefully remove the cartridge 

e)

 

Holding  the  plastic  section  of 

the cartridge firmly in on hand, turn 
on  the  main  cold  water  tap  and 
place  the  ceramic  part  of  the 
cartridge  under  the  water  flow.  
Gently brush the ceramic with a stiff 
brush to reveal a clean surface. 

f)

 

Warning:

  Never  use  detergents 

or  anything  other  than  water  for 
cleaning.    Never  twist  or  knock  the 
ceramic,  as  it  is  brittle  and  will 
crack  if  abused.

  NOTE  that  the  JP 

CERAMICS CARTRIDGE TYPE B is not 
recleanable.

  The  inside  of  the 

housing  will  become  coated  with 
dirt,  rust  and  particulates.  This  is 
not important, as this is on the dirty 
side of the filter, it is only important 
to  keep  the  outlet  side  of  the  filter 
clean. 

g)

 

Place  three  disinfectant  tablets 

in  the  housing  and  replace  the 
cartridge.  For  the  MP2K  three 
tablets  should  be  placed  into  each 
housing.

 

h)

 

CHECK  THAT  THE  INTERNAL 

SUMP  ‘O’  SEAL  IS  IN  PLACE  and 
follow  the  procedure  set  out  in 

Section Three, Step 9.

 

Note: 

White  water.  When  a  fresh 

ceramic  cartridge  is  installed  or 
after  cleaning,  the  water  may 
appear “white” for a short while.

 

Summary of Contents for MP1K

Page 1: ...ystem has a single multi technology cartridge contained within a single housing The MP2K gives additional performance and a longer cartridge life It comprises two durable plastic housings and two uniq...

Page 2: ...p 7 The MP1K comprises one cartridge 4 with seal 5 in one housing The MP2K has two sumps 8 9 the first of which contains the Type A cartridge The second housing contains the Type B cartridge fig 2 How...

Page 3: ...s To seal the cartridges into the headwork s within the plastic housing the upper spigot thread of the cartridge threads into the head works using the candle sealing washer 5 THIS SEAL IS ESSENTIAL TO...

Page 4: ...ish to drill The tape will prevent the drill bit from walking Using carbide drill bits commence drilling in the middle of the tape first using a 3 125mm 1 8 inch drill bit to make a pilot hole After d...

Page 5: ...o 3 inches under the housing is all that is needed Also determine the best location to permit connection to the red inlet and blue outlet flexi pipe tubing When fitting the tubing make certain that it...

Page 6: ...ticulate material will collect on the outside surface of the ceramic membrane and this will reduce the water flow rate If the line piercing valve is fully open and the flow rate becomes unacceptably l...

Page 7: ...becoming blocked as it collects the unwanted debris and pollutants from the water See cleaning instructions Section Three Step 2 d Check that the line piercing valve is fully opened or if there is lo...

Page 8: ...rom a leak e may run along the pipe work it may drip or collect some distance form the actual position of the leak f When the leak is found if it is an O seal first clean the seal and the surrounding...

Page 9: ...Only available with upgrade 1 1 CI3112U7s Speed fit tap adapter 7 16unf 3 8 1 1 TB P 3 8 6 Blue flexi pipe tubing 1 1 TB PR 3 8 2 Red Flexi pipe tubing 1 1 LPV03 1 Opella Line piercing valve for 15mm...

Reviews: