Electrical Connections
1. The extractor fan must be connected to a single
phase mains network, 220 - 240VAC.
2. The installation must have an omnipolar switch
with a contact separation of at least 3mm. The
circuit must be protected by either a 3 Amp fuse
or suitable 3A MCB.
3. Earthing is not required as this extractor is a
class II insulated appliance.
4. The extractor must be connected permanently
to a fixed installation cable secured in fixed
channelling. (Flex of two conductor wires of
minimum section 1mm
2
and maximum 1.5mm
2
)
To make the Electrical Connections
1. Loosen the 4 screws (A) and take off the
connection cover
2. Perforate the flex holder (B) to allow the power
supply wires to pass through.
3. Make the connections as indicated on the
next page.
N.B Make sure that once the extractor is installed there is no accidental access to the moving parts.
B
A
Flexible
ducting
TF fan
mounted
External
grille
Internal
grille
Body can be rotated to accomodate tight spaces.