Check List before Use

 

 

Component 

Inspection required 

Generic 

Visual inspection of the external of the Shower Trolley. Significant damage that 

may affect the function of the Shower Trolley along with a clear safety hazard is 

unacceptable. 

Check the Labelling on the Shower Trolley to ensure they are all still legible, this 

includes the Serial Number and other important markings. If labels are not legible, 

then contact your local authorised dealer immediately. 

Check all main nuts and bolts to see if they are loose, If they are not tight or you 

have concerns, then contact your local authorised dealer immediately. 

Actuator

 

The actuator should not require maintenance other than checking for correct 

operation, listening for unusual noise and checking for any damage. Ensure the 

actuator does not lower when the load is applied.

 

Side Rails 

Ensure the Side Rails are functioning correctly, and can be securely locked in place 

with the pin. 

Head Rail / Foot Rail 

Ensure the Star Handles are tight and that the Rails cannot become loose.  

Drainage Pipe 

Ensure the Drainage Pipe is secured properly and is not leaking. If damaged, seek a 

replacement.  

Plug 

Ensure the Plug is either fitted or available when required.  

Foot Lever 

Ensure the Foot Lever is functioning as intended and safe to use prior to raising 

the patients’ height.  

Castors

 

Check all castor fixing points. Check that each castor runs free and rotates easily. 

Remove any build-up of hair, fluff, dust etc. Ensure there is no visible deformation 

to the castors. Any damage will require immediate replacement. 

 

Check the brake functionality of all the castors. 

Pivot Points

 

Inspect the pivot points of moving parts for any wear that may affect the Trolleys 

function.

 

 

 

 

9.3

 

Cleaning

 

Please follow the cleaning guidelines below on cleaning and disinfecting the Shower Trolley.

 

 

9.3.1

 

General cleaning 

 

It is recommended to clean the Freeway Height Adjustable Shower Trolley before the use by a different patient, 

reducing the risk of cross–contamination. 

 

The exterior of the Shower Trolley can be cleaned using a damp soapy cloth for general cleaning duties. Please ensure the cloth 

is damp and not wet. Ensure the exterior of the device is dry after cleaning. Dry using a clean dry cloth. 

 

 

 

 

 

9.3.2

 

Disinfecting (if necessary) 

Should the Shower Trolley require a more thorough clean, the use of the Actichlor™ disinfectant product (which is widely 

available in tablet form and used throughout the health care industry) is recommended. 

Table 8

 

Summary of Contents for Height Adjustable Shower Trolley with Liner 1500mm

Page 1: ...18 03 21 Height Adjustable Shower Trolley User Manual This document includes the following models Height Adjustable Shower Trolley with Liner 1500mm Height Adjustable Shower Trolley with Liner 1700mm...

Page 2: ...10 3 3 1 Liner and Drainage Pipe 10 3 3 2 Head Rail and Foot Rail 11 3 3 3 Final Assembly 11 Operating instructions 12 4 1 Manoeuvring the Shower Trolley 12 4 2 Brakes 12 4 3 Head Rail and Foot Rail 1...

Page 3: ...f 28 Disposal 17 Fault Finding 18 General Inspection Maintenance and Cleaning 19 9 1 Service 19 9 2 Inspection 19 9 3 Cleaning 20 9 3 1 General cleaning 20 9 3 2 Disinfecting if necessary 20 Warranty...

Page 4: ...without prior written notice If during the use of this device or as a result of its use a serious incident has occurred please report it to the manufacturer and to your national authority Do not attem...

Page 5: ...ons before use Caution see instructions for use Manufacturer Safe Working Load represents the maximum load rated for safe operation Packaging indicator This way up Date of manufacture Serial number Pa...

Page 6: ...on the dignity and wellbeing of the person being moved the simple to use trolley maximises the amount of care provided to the person The Shower Trolley has the option of height adjustments allowing a...

Page 7: ...ement You may need to seek specialist advice on how to assist some people with specific bathing needs Sources of advice include but is not limited to professional bodies and organisations occupational...

Page 8: ...ived all the components contact Prism Medical UK dealer immediately contact details are provided on the last page of this manual Item Description Item Description 1 Support Frame 8 Drainage Pipe with...

Page 9: ...he Shower Trolley The environment in which the Shower Trolley is situated in whilst carrying out a transfer is required to be on a flat surface with no steep inclines 3 2 Unboxing Shower Trolley When...

Page 10: ...ockwise until it is secure and tight See Figure 6 Ensure the threaded pipe fixing is secured tight to avoid inadvertent detachment E Attach the pipe by rotating the thread anticlockwise until it is se...

Page 11: ...igure 9 B Slide the Head Foot Rail into the slots ensure the rail is correctly orientated with the rail facing upward as shown in figure 10 C Tighten the Star Handles to secure the Rails The rail posi...

Page 12: ...2 Brakes A The Freeway Height Adjustable Shower Trolley has four braked castors B The castors should can be applied when parking adjusting the Trolley height avoiding lateral movement using to rotate...

Page 13: ...m height it will be noticeable that the lever operation no longer decreases the height 4 5 Side Rails The Side Rails ensure the patient does not fall from the mattress support the side rails are also...

Page 14: ...076 Revision A P a g e 14 of 28 Technical Specification 5 1 Freeway Height Adjustable Shower Trolley Dimensions Below are the dimensions of the 1900mm Adjustable Height Shower Trolley Figure 22 Figure...

Page 15: ...r Trolleys included in this Manual Description Min Height Max Height Inside Length Min Overall Length Max Overall Length Inside Width Overall Width A B min B max AH Shower Trolley 1500mm 860 1185 1500...

Page 16: ...l Forces Moving Force with 200 kg 115N Moving Force with 0 kg 28N Operation of the Brake 107N Operation of the Foot Lever with 0 kg 75N Operation of the Foot Lever with 200kg 267N 5 3 Expected Product...

Page 17: ...r perform to its intended use safely the Shower Trolley must be decommissioned by an approved Service Engineer The following specifies the importance of correct disposal procedure including local laws...

Page 18: ...or any tears or holes Castors are not operating as intended Ensure the Brake has been fully disengaged Inspect the Castors for clear deformation which is affecting its function Ensure the Castors are...

Page 19: ...pare Parts Manual Document Number 992076 The Service must be completed every 6 months after installation of the Shower Trolley to ensure the trolley is safe for use The Freeway Height Adjustable Showe...

Page 20: ...ed seek a replacement Plug Ensure the Plug is either fitted or available when required Foot Lever Ensure the Foot Lever is functioning as intended and safe to use prior to raising the patients height...

Page 21: ...d contact time The device can withstand a longer contact period but the 5 minute recommendation as a minimum must be followed to provide an effective cleaning regime Blood spills should be dealt with...

Page 22: ...ease follow the link below http www nhsggc org uk media 236215 msds actichlor plus pdf Warranty This guarantee does not affect or in any way limit your Statutory Rights 1 Prism Medical UK guarantees t...

Page 23: ...999076 Revision A P a g e 23 of 28 Service Record History Complete this section after each service repair inspection and or maintenance...

Page 24: ...999076 Revision A P a g e 24 of 28...

Page 25: ...999076 Revision A P a g e 25 of 28...

Page 26: ...999076 Revision A P a g e 26 of 28...

Page 27: ...999076 Revision A P a g e 27 of 28 User notes...

Page 28: ...K for any errors or omissions Prism Medical UK operates a policy of continuous improvement Specifications and other data are subject to change without notice Dealer service contact details Prism Medic...

Reviews: