background image

5B5-01

BG BT

BH

MH

A

B

GD

OP

NH

NG

FREE-WAY

HSS Parallel Series Scheme 1V/1T

Model No:-

5

N

M

B

4

3

2

1

IN PARALLEL

10

9

8

7

6

IN SERIES

NH

OP

GD B

A

MH

BG

BT

BH

NG

TIP

RING

B   +   M

M + N

IN SERIES

IN PARALLEL

Humbucker

FRONT VIEW OF PICKUPS AND SWITCH

FRONT VIEW OF PICKUPS AND SWITCH

REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.

T

NECK

MIDDLE

BRIDGE

GROUND WIRES TO CAVITY

SHIELD & SPRING CLAW

V

N

ote

: te

rm

ina

ls

A,

B

&

BG

are

no

t u

se

d.

5B5-01

Hot

Grd

Hot

Grd

Switch metalwork is assumed to be grounded by shielding on
reverse of scratch-plate which is assumed grounded via the potentiometers

Refer to Free-Way Blade Installation Instructions

Note: ensure all pickups are of compatible phase/polarity

Inr/Coil

Otr/Coil

Otr/Coil Finish wire

Inr/Coil Finish wire

Inr/Coil Start wire

Otr/Coil Start wire

HUMBUCKER COLOUR KEY

Shield wire

Scheme No B006 : Last Updated Jul 2018

© Free-Way 2018

Summary of Contents for 5B5-01

Page 1: ...urers instructions Check that the Free Way Blade Switch will fit refer to dimensional information provided Use 22 AWG Wire strip insulation back 5mm twist strands and locate into terminal holes Make any daisy chain links and locate these into one of the terminal hole pairs Solder using multi core solder Ensure solder joint is clean and flows about terminal pad Avoid excessive solder avoid contacti...

Page 2: ...S AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH REVERSE VIEW OF PICKUPS SWITCH AND POTENTIOMETERS TN TM V NECK MIDDLE BRIDGE GROUND WIRES TO CAVITY SHIELD SPRING CLAW Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions Note term inal A is not used Scheme No B001 Last Upd...

Page 3: ... PICKUPS AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH REVERSE VIEW OF PICKUPS SWITCH AND POTENTIOMETERS TN TM V NECK MIDDLE BRIDGE GROUND WIRES TO CAVITY SHIELD SPRING CLAW Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions 5B5 01 Hot Grd Hot Grd Hot Grd Scheme No B003...

Page 4: ...ECK MIDDLE BRIDGE Inr Coil Otr Coil GROUND WIRES TO CAVITY SHIELD SPRING CLAW V Otr Coil Finish wire Inr Coil Finish wire Inr Coil Start wire Otr Coil Start wire HUMBUCKER COLOUR KEY Shield wire Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions Note term inals A B BG...

Page 5: ... SWITCH FRONT VIEW OF PICKUPS AND SWITCH REVERSE VIEW OF PICKUPS SWITCH AND POTENTIOMETERS T V NECK MIDDLE BRIDGE GROUND WIRES TO CAVITY SHIELD SPRING CLAW Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions Note term inal A is not used 5B5 01 Hot Grd Hot Grd Hot Grd S...

Page 6: ...OF PICKUPS AND SWITCH FRONT VIEW OF PICKUPS AND SWITCH REVERSE VIEW OF PICKUPS SWITCH AND POTENTIOMETERS T V NECK MIDDLE BRIDGE GROUND WIRES TO CAVITY SHIELD SPRING CLAW Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions 5B5 01 Hot Grd Hot Grd Hot Grd Scheme No B004 L...

Page 7: ...K MIDDLE BRIDGE GROUND WIRES TO CAVITY SHIELD SPRING CLAW V Note term inals A B BG are not used 5B5 01 Hot Grd Hot Grd Switch metalwork is assumed to be grounded by shielding on reverse of scratch plate which is assumed grounded via the potentiometers Refer to Free Way Blade Installation Instructions Note ensure all pickups are of compatible phase polarity Inr Coil Otr Coil Otr Coil Finish wire In...

Reviews: