LRS400S Data Transceiver Users Manual
LUM0025AA Rev A
Version 1.0
21
(C)
R
EMOTE
LED
This setting enables the user to connect Remote LED’s through the diagnostics port.
Setting
Description
Notes
0
Board LED’s
Default. Only on board LEDs are enabled.
1
Board and Remote LED’s
Onboard LED’s are enabled as well as
Remote LED’s through the Diagnostic port.
2 Remote
LED’s
On board LED’s are disabled. Remote LED’s
are enabled through the Diagnostic port.
Note
: When using Remote LED’s the center (TX) LED will not turn Green when in Setup mode. This line