Table 3 below is similar to the Table 2, but shows the information for the 8.15 dB Yagi 
antenna. 
 

 
 
 

 

 

 
 
Follow the steps below to configure the Power Output Level: 
 

9

  Connect to the transceiver’s Web page (See the HT Plus User Manual for further 

instructions). 

 

9

  Click the “Radio Setup” Link. 

 

9

  Choose an appropriate setting in “Transmit Power”, as defined from the previous tables. 

 

9

  Click the “Save Changes” button. After the page refreshes, click the “Reboot” button and 

wait for the transceiver to restart. 

 
 

6. 

Repeat the steps above for each transceiver in the network.

 

 

 

NOTE:

 Please, be advised that antennas other than listed in this section can potentially be 

used with the transceiver provided that:  

 

these antennas are of a similar type to the listed above; 

  antenna gain does not exceed 8.15 dBi for omni-directional and 12.15 dBi for 

directional antennas 

 

overall system EIRP does not exceed 36 dBm. 

 

WARNING: Any antenna other than listed in this section needs to be approved by 

FreeWave Technologies before its use to assure that the transceiver in 
combination with the new antenna meets FCC requirements. 

 
 
 
 
 
 
 
 

Table 3:    

EIRP for 8.15 dBi Yagi Antenna, Cable loss vs. 

RF Xmit Power Setting. 

Cable Loss 

 

  1dB 2dB 3dB 4dB 

RF Xmit 

10

36.55 

35.55 34.55 33.55 

Power 

9

36.25 

35.25 34.25 33.25 

 

8

35.25 34.25 33.25 32.25 

 

7

34.05 33.05 32.05 31.05 

 

6

32.75 31.75 30.75 29.75 

Summary of Contents for HTP-900RE

Page 1: ...G0007AA V1 0 RevC 1 of 8 900 MHz Wireless Ethernet Modem Terminal Server model HTP 900RE Installation Guide v 1 0 Rev C FreeWave Technologies Inc 1880 S Flatiron Ct Suite F Boulder CO 80301 303 444 38...

Page 2: ...gh Throughput DST transceiver sold under FCC ID KNY 820181531119 All transceiver models sold under FCC ID KNY 820181531119 must be installed professionally This transceiver is only approved for use wh...

Page 3: ...for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment g...

Page 4: ...The enclosures shall also have provisions for Division 2 wiring methods as specified in the National Electrical Code or Canadian Electrical Code as applicable 2 The transceivers must be used within t...

Page 5: ...ion However there is one parameter that must be considered for a new installation the transceiver s power output setting Transmit Power Radio Setup page Transmission Characteristics section Transceive...

Page 6: ...as an example and cable loss combinations NOTE It is the installer s responsibility to ensure that the emission limits are not exceeded Table 2 below shows how the Transmit Power settings on the radi...

Page 7: ...Repeat the steps above for each transceiver in the network NOTE Please be advised that antennas other than listed in this section can potentially be used with the transceiver provided that these ante...

Page 8: ...tenna is critical to a solid data link Other antennas in close proximity are a potential source of interference use the Radio Statistics or Diagnostics software to help identify potential problems It...

Reviews: