When using an external antenna, placement of that antenna is critical to a solid data link. Other
antennas in close proximity are a potential source of interference; use the Radio Statistics or
Diagnostics software to help identify potential problems. It is also possible that slight adjustments
in antenna placement (as little as 2 feet) will solve noise problems. In extreme cases, such as
when the transceiver is located close to Pager or Cellular Telephone transmission towers,
FreeWave offers a band pass filter to reduce the out of band noise.
C. Diagnostic ports:
The FGRplusRE does not use the diagnostic port.
The radio cannot be programmed through
the diagnostic cable.
D. Power Connection
The FGRplusRE transceivers can be operated from any Class 2 power source, input voltages of
6V to 30V. The power source should be capable of providing at least 550 milliamps of continuous
current at 12V DC.