MCM_PLAMC field descriptions
Field
Description
15–8
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
7–0
AMC
Each bit in the AMC field indicates whether there is a corresponding connection to the AXBS master input
port.
0
A bus master connection to AXBS input port
n
is absent
1
A bus master connection to AXBS input port
n
is present
18.2.3 Crossbar Switch (AXBS) Control Register (MCM_PLACR)
The PLACR register selects the arbitration policy for the crossbar masters.
Address: E008_0000h base + Ch offset = E008_000Ch
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
R
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
R
W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
MCM_PLACR field descriptions
Field
Description
31–10
Reserved
This field is reserved.
This read-only field is reserved and always has the value 0.
9
ARB
Arbitration select
0
Fixed-priority arbitration for the crossbar masters
1
Round-robin arbitration for the crossbar masters
8–0
Reserved
This field is reserved.
Chapter 18 Miscellaneous Control Module (MCM)
K22F Sub-Family Reference Manual , Rev. 3, 7/2014
Freescale Semiconductor, Inc.
391