background image

 

ISED Statement 

 

English: This device complies with Industry Canada license

exempt RSS standard(s). 

Operation is subject to the following two conditions: (1) This device may not cause interference, a 
nd (2) This device must accept any interference, including interference that may cause undesired 
operation of the device. 
The digital apparatus complies with Canadian CAN ICES

3 (B)/NMB

3(B). 

 

French: Le présentappareilestconforme aux CNR d'Industrie Canada applicables aux appareils 

radio exempts de licence. L'exploitationestautorisée aux deux conditions suivantes: (1) l'appareil 
ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareildoit accepter tout brouillageradi 
oélectriquesubi, mêmesi le brouillageest susceptible d'encompromettre le fonctionnement. 

l'appareil num

é

rique du ciem conforme canadien peut  

‐ 

3 (b) / nmb  

‐ 

3 (b). 

 

This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and 
compliance  with  RSS  102  RF  exposure,  users  can  obtain  Canadian  information  on  RF  exposure  
and compliance. 

 

cet appareil est conforme à l'exemption des limites d'évaluation courante dans la section 2.5 du 
cnr  - 102  et  conformité  avec rss 102  de  l'exposition aux  rf,  les utilisateurs  peuvent  obtenir  des 
données canadiennes sur l'exposition aux champs rf et la conformité. 

 

This equipment complies with Canada radiation exposure limits set forth for an uncontrolled 
environment. 
Cet équipement est conforme Canada limites d'exposition aux radiations dans un environnement 
non contrôlé. 

 

This equipment should be installed and operated with minimum distance 0cm between the 
radiator & your body. 
Cet équipementdoit être installé et utilisé à une distance minimale de 0 cm entre le radiateur et 
votre corps. 

 

ISED Modular Usage Statement 

NOTE 1: When the ISED certification number is not visible when the module is installed inside 
another device, then the outside of the device into which the module is installed must also 
display a label referring to the enclosed module. This exterior label can use the 

wording ”Contains transmitter module IC: 

28247-FNRFIDRC522

” or “Contains IC: 

28247-

FNRFIDRC522

”.

 

 

NOTE 1: 

Lorsque le numéro de certification ISED n'est pas visible lorsque le module est installé 

dans un autre appareil, l'extérieur de l'appareil dans lequel le module est installé doit également 

afficher une étiquette faisant référence au module inclus. Cette étiquetteextérieure peut être 

libellée Contient le module émetteur IC: 28247-FNRFIDRC522 ou Contient IC: 28247-FNRFIDRC522. 

Summary of Contents for RFID-RC522

Page 1: ...munication technology Project 1 Read UID In this project we will read the unique ID number UID of the RFID card recognize the type of the RFID card and display the information through serial port Component List Freenove UNO x1 RC522 RFID Module x1 Mifare1 S50 Standard card x1 Mifare1 S50 Non standard card x1 USB able x1 Jumper F M x7 ...

Page 2: ...he main operating frequency of Passive RFID products are 125KHZ low frequency 13 56MHZ high frequency 433MHZ ultrahigh frequency 915MHZ ultrahigh frequency Active and semi active RFID products work at higher frequencies The RFID module we use is a passive RFID product with the operating frequency of 13 56MHz Component Knowledge MFRC522 RFID Module The MFRC522 is a highly integrated reader writer I...

Page 3: ...lobal unique identifier number USN UID which can be rewritten 100 thousand times and read infinite times Its storage period can last for 10 years The ordinary Mifare1 S50 Card and non standard Mifare1 S50 Card equipped for this kit are shown below Mifare1 S50 Standard card Mifare1 S50 Non standard card The Mifare1 S50 capacity 1K byte is divided into 16 sectors Sector0 Sector15 Each sector contain...

Page 4: ...ontrol block including a 6 byte password A 4 byte access control and 6 byte password B For example the control block of a brand new card is as follows A0 A1 A2 A3 A4 A5 FF 07 80 69 B0 B1 B2 B3 B4 B5 password A access control password B The default password of a brand new card is generally A0A1A2A3A4A5 for password A B0B1B2B3B4B5 for password B or both the password A and password B are 6 FF Access ...

Page 5: ...5 RFID www freenove com Circuit The connection of Freenove UNO board and RFID module is shown below Schematic diagram Hardware connection ...

Page 6: ... char str MAX_LEN MAX_LEN is 16 size of the array void setup Serial begin 9600 SPI begin rfid init initialization Serial println Please put the card to the induction area void loop Search card return card types if rfid findCard PICC_REQIDL str MI_OK Serial println Find the card Show card type ShowCardType str Anti collision detection read card serial number if rfid anticoll str MI_OK Serial print ...

Page 7: ... to the SDA pin and the RST pin 5 RFID rfid 10 9 In setup initialize the serial port SPI and RFID 11 12 13 Serial begin 9600 SPI begin rfid init initialization In loop use findCard waiting for the card approaching Once it detects card contact this function will return MI_OK and save the card type data in parameter str Then enter the if statement 20 if rfid findCard PICC_REQIDL str MI_OK After ente...

Page 8: ...NO open the serial port monitor and make a card approach the sensing area of RFID module Then serial port monitoring window will display the displacement ID number and the type of the card If the induction time is too short it may lead to incomplete information display ...

Page 9: ...es with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 0cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Country Code selection feature to be disabled for products marketed to the US Canada This device is inten...

Page 10: ...r your body 2 7 Antennas This radio transmitter FCC ID 2A4TN FN RFID RC522 has been approved by Federal Communications Commission to operate with the antenna types listed below with the maximum permissible gain indicated Antenna types not included in this list that have a gain greater than the maximum gain indicated for any type listed are strictly prohibited for use with this device Antenna No Mo...

Page 11: ...é avec rss 102 de l exposition aux rf les utilisateurs peuvent obtenir des données canadiennes sur l exposition aux champs rf et la conformité This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment Cet équipement est conforme Canada limites d exposition aux radiations dans un environnement non contrôlé This equipment should be installed and operated...