NOTE: The caulking must be allowed to cure before assembly 
of the unit.

7. Carefully position the shower base so it sits on the front 

mounting flanges. Install the drain fitting in accordance with 
instructions provided with the fitting. Do not allow the base 
to sit on the drain fitting.

8. Review the framing diagram illustrated in 

Figure 1

. The 

diagram details the method of installation of the EasyBase

self leveling reinforced bottom. When installing, it is 

ESSENTIAL to assure the ENTIRE bottom of the shower 

be securely adhered to the building floor. The shower will 

not drain properly unless the bottom is properly installed in
accordance with these provided installation instructions. 
Review 

Figure 1

 and read these instructions thoroughly 

when planning you installation. Failure to install the unit in 
accordance to these provided instructions will void the 
warranty.

Accessibility Professionals are not responsible for 
installations that do not adhere to these provided 
instructions.

9. Study framing diagram and note the important 
installation requirements.

Note that Thin-Set mortar is used in the DRAIN CORE ONLY. 

Fill the drain core only 2/3rds full of Thin-Set. Do not 
overfill as this will prevent proper floor draft and may push 

the drain area up causing the unit not to drain properly.

The shower base is installed separately from the wall 

sections. Before applying any Thin-Set or Adhesive, trial fit
the shower base to confirm the alcove is of proper size and 

the drain is located properly.

10. The ENTIRE bottom is adhered to the Sub-Floor using 

3M Polyurethane Construction Adhesive (or equivalent).

This includes the entire bottom minus the drain core.

11. Note in the FRAMING DIAGRAM that construction 

adhesive is spread over the entire area where the 
EasyBase

 is in contact with the Sub-Floor. This includes the 

front threshold area.

12. Before beginning installation, it is ESSENTIAL that the 
sub floor in the installation area be completely clean. It 

4. Modify framing if required. There should be a framing 

member behind each flange. Make sure your framing is plumb 

and square.

5. Planning is necessary for Tin-Set mortar or 100% silicone 
adhesive to be placed in the drain core area for all installations. 
Proper blocking is required to prevent the Thin-Set from 

flowing to the floor below.

 

Showers configured with the factory installed EasyBase

 

self leveling, reinforced bottom will be installed using panel 
adhesive. However, wet mud will be used in the drain core 

area on these units. 

See Figure 1.

INSTALLATION INSTRUCTIONS

1. Before you disassemble the shower unit, transfer the 

locations for the supply valve and shower head on the unit.

Mark these locations on the back (reinforced surface) of the 
unit. After double checking the locations, drill 1/4” pilot holes.

2. Always place cardboard or a drop cloth in the shower base 

to protect the finished surface. Working from the finished side 
of the unit, using the proper size hole saw, cut holes for supply 

lines and shower head.

3. Remove the connection bolts and disassemble the unit. If 

present, remove shower rod. Carefully carry the parts to the 
installation area. Do not flex the parts when moving to avoid 

scratches and stress cracks.

4. The shower may be reassembled and installed in one piece 

if there is sufficient room. Typically, the parts are installed 

piece by piece starting with the base. If installing in one 

piece, the metal nuts and bolts will be used for permanent 

connection. The installer must apply 100% silicone caulking to 

all connection surfaces for final installation.

5. When installing piece by piece, use the pin system in place of 
the nuts and bolts. The pins will act as guides that will index the 

parts together for installation where access to the back side in 
unavailable.

6. Apply a liberal amount of 100% silicone caulk to each pin 
before inserting them through the holes. 

Insert the plastic fasteners through the holes from below so 
they point to the ceiling.