Freedom Lift Systems Trus-T-Lift 750 Maintenance Manual Download Page 9

 

 8 | 

P a g e

 

TRUS<T>LIFT™ 750 LIMITED MAINTENACE MANUAL REVISION A, 16AUG2016 

 

4.9

 

Verify that disconnects function correctly 

Verify that when the disconnects are 

ipped power to the li

ft

 is cut o

 and, if this is a 

commercial li

ft

, the interlocks at each landing (when the li

ft

 is in the correct posi

ti

on will 

open) and that the alarm and light on board the carriage are ac

ti

ve. 

4.10

 

Verify that key switches at each location function correctly 

Verify that when a key switch at each landing or on board the li

ft

 is turned to the 

off 

posi

ti

on the corresponding bu

tt

ons and control paddles do not operate the li

ft

4.11

 

Additional Redundancy Tests for Commercial Applications 

For commercial li

ft

s there are o

ft

en addi

ti

onal redundancy tests required to be completed 

during inspec

ti

on. To prepare for an inspec

ti

on where these are required RAM suggests 

doing the tests prior to the inspec

ti

on so that the func

ti

ons are c

onfi

rmed. 

RAM will typically include a copy of these redundancy procedures in a commercial li

ft

 

package but if you do not have them please contact RAM and we will supply a copy. 

 

Section 5:

 

Maintenance Log: 

Please keep a record of all maintenance done on the li

ft

 in the maintenance log provided in 

Appendix C.  

 

 

Please have your serial number ready if you call RAM directly so we 

can determine what li

ft

 you have. 

Serial Number is located inside of the control panel door. 

 

Summary of Contents for Trus-T-Lift 750

Page 1: ...Trus T Lift 750 Limited Maintenance Manual Copyright 2016 Revision B Oct 3 2016 Phone 1 877 947 7769 www FreedomLiftSystems com...

Page 2: ...nty null and void The lift is intended for use by people and not to be used for cargo or other purposes Lifting capacity is up to a maximum of 750 lb unless otherwise noted on the lift and in RAM s su...

Page 3: ...intenance by technician The Trus T Lift should be inspected and maintained annually The following is a non exhaustive list items of that should be checked as part of an annual maintenance in order to...

Page 4: ...el surfaces resulting in scratches Small points of damage can be wire brushed and touched up with the small touch up paint containers that come with each lift RAM ships out This will extend the life a...

Page 5: ...llation for mechanical and electrical items is complete to ensure that the lift is operating correctly All lifts are tested at the factory but they are then disassembled and shipped to sites across No...

Page 6: ...quipped with an upper limit switch that indicates to the control circuitry when the lift has reached the upper landing This will be set as part of the installation process but you should physically an...

Page 7: ...Verify Bypass Switch Operation If your lift comes equipped with a BYPASS switch you will need to verify that it operates correctly The BYPASS switch is used to allow the lift to operate within 50mm of...

Page 8: ...me cases 4 6Verify Door and Gate Interlocks Depending on the number of landings you have each door interlock should be checked so that if the platform is not at the landing location the door or gate w...

Page 9: ...perate the lift 4 11 Additional Redundancy Tests for Commercial Applications For commercial lifts there are often additional redundancy tests required to be completed during inspection To prepare for...

Page 10: ...9 P a g e TRUS T LIFT 750 LIMITED MAINTENACE MANUAL REVISION A 16AUG2016 Appendix D Maintenance Log Date Description Signed...

Reviews: