Free2Move eSolutions eProWallbox Installation Manual Download Page 8

Parameter

: DPM_PMAX

This

 field contains the

 

contract

ual 

power expressed in Watt

 

UUID

: b4bc4914-1381-4294-acb0-776947becb9d

TYPE

: Uint32, select UINT32 on the app

VALUE

: min value 0, max value 70000

1.

Identify

 the

UUID

 of the D

P

M

Pmax

 parameter

2. Click on the

up arrow

 next

to the Unknow
characteristic

3. Select

 

UINT32

 

4. In "New value"

field insert the

 

contractual

 

power value,

 

expressed in

 

Watt,

 

from 0 to

 

70000

.

Then click 

SEND

5. The new value
will appear on
the main page,
expressed in bytes

8

3

.

2

 

DPM

a.

 

DPM P

MAX

A d v a n c e d   f u n c t i o n a l i t i e s   s e t u p

Installation manual - Annex

  

Summary of Contents for eProWallbox

Page 1: ...EN A d v a n c e d f u n c t i o n a l i t i e s s e t u p Installation manual Annex...

Page 2: ...OF CONTENTS SECTION PAGE 1 INTRODUCTION 3 2 PROCEDURE 5 DPM 8 a DPM ENABLING 9 b DPM Pmax 8 DPM 2 0 4 Energy meter configuration 7 LOAD UNBALANCE 10 a Load unbalance enabling 11 b Load unbalance curr...

Page 3: ...d via Bluetooth DPM DPM enabling DPM Pmax DPM 2 0 Electrical Installation Configuration Transformer ratio KI DPM Type selection Load Unbalance Load unbalance enabling Load unbalance current A d v a n...

Page 4: ...ough the clamp the line according to the direction indicated on the sensor The neutral cable must not be drawn through the clamp 5 Use the following order for connecting the communication cables from...

Page 5: ...Open nRF Connect and Set a filter e g ePro in order to see only eProWallboxes in the homepage 3 Select Scan on the top right corner to identify the eProwallbox to be connected via Bluetooth through it...

Page 6: ...uetooth The UUID is associated to a specific functionality By clicking on the down arrow the specifics of the parameters will be displayed By clicking on the up arrow a new command can be set through...

Page 7: ...onnect app Parameter DPM_TYPE This field allows to select the Power Meter model installed UUID f0f924f8 34ce 4f1d 9791 b1b19ff3ffe4 TYPE Uint8 select UINT8 on the app VALUE 00 FINDER 3ph 212 01 FINDER...

Page 8: ...1 Identify the UUID of the DPM Pmax parameter 2 Click on the up arrow next to the Unknow characteristic 3 Select UINT32 4 In New value field insert the contractual power value expressed in Watt from 0...

Page 9: ...Identify the UUID of the DPM Enabling parameter 2 Click on the up arrow next to Unknow characteristic 3 Select BYTE 4 In New value field insert 01 to ENABLE 00 to DISABLE Then click SEND 5 The new val...

Page 10: ...ect BYTE on the app VALUE 00 FALSE disabled 01 TRUE enabled b Load unbalance current Parameter LOAD_UNBALANCE_CURRENT Thisvaluedefinesthemaxallowable phases currentunbalanceexpressed in mA UUID f9217d...

Page 11: ...Registered office Free2move eSolutions S p A Piazzale Lodi 3 20137 Milan Italy esolutions free2move com...

Reviews: