TPA400 Rev0509
5
Specifications
Display Module
Supply Power:
12 VDC
Supply Current:
1.5 Amps
Dimensions:
4.4" by 4.4" by 3.5"
Audible Alarm Buzzer
Voltage:
12 VDC
Volume:
95 dB
Sensors
Note: Sensors are used when information is not available on the J1587 data
link. The sensors needed will vary with the specific engine.
Oil Pressure:
0 - 100 PSI, 1/8" NPTF, 240-33 Ohms
Coolant Temperature:
100 - 250 °F, 1/2"-14 NPT
50 - 300 °F, 5/8" - 18 UNF (Ford 6.0 L)
Gen. Engaged Sensor:
120 VAC
Trans. Temp. Sensor:
140 - 320 °F, 1/8" NPTF, 240-33 ohm
Pump Overheat:
Close 130 °F; Reset 115 °F
RPM:
Input signal from alternator or flywheel
Note: For TPA406 Ford 6.0L engines it is best to pick up the RPM from the
Clean Tachometer Signal (green/white) wire. If connecting to the alternator,
ensure the signal is not a low level (less than 1.5 volts), if it is the flywheel
or magnetic pick-up connection must be used.