DGA200 Rev160525
28
OPERATION
The DryGear system blower operates independently from the heater and can be
powered alone to circulate room temperature air.
Overheat Protection
The heater can not be powered without the blower running, this is to prevent the
heater from overheating. An internal thermistor cuts power to the heater and blower
if the heater temperature rises above 180 °F. The heater and blower power is back on
when the heater temperature falls below 150 °F.
Procedure
Hang coat and pants on hanger assembly, put gloves over glove posts, helmets and
hoods may be set on top of the manifold, boots and other equipment may be placed
inside the enclosure.
Remove the hanger assemblies (DryGear Plus only) to roll in racks of hose or
loose equipment.
1. Place
SELECT
switch to
AIR ONLY
position.
NOTE:
If the timer is to be set for less than one hour the timer switch must
be turned clockwise past 1 and than back to desired time.
2. Set
BLOWER & HEATER HOURS
switch to desired time.
Result: The blower goes on. Room temperature air is circulated in the DryGear
enclosure.
3. Place
SELECT
switch to
AIR & HEAT
position.
Result: The
HEATER SELECTED
lamp goes on. Heated air is circulated in
the DryGear enclosure.
4. Close the tent front cover and zip up the sides (zip up the center on 6, 7, and
8 station configurations).
NOTE:
Some air will escape from the bottom of the enclosure to disperse
moisture. Do not attempt to make an air tight seal to the floor.
End Procedure