background image

IONFIX PRO 

STATIC GENERATOR WITH REMOTE 

MONITORING AND CONTROL INTERFACE

QUICK START GUIDE

Summary of Contents for IONFIX COMPACT

Page 1: ...IONFIX PRO STATIC GENERATOR WITH REMOTE MONITORING AND CONTROL INTERFACE QUICK START GUIDE...

Page 2: ......

Page 3: ...medical attention If the generator is to be operated by ordinary persons it must be installed in such a manner that the high voltage output connectors are not accessible in normal operation for examp...

Page 4: ...n energised Refer to the full manual for detailed installation instructions 1 Ensure that the generator is correctly earthed as described above 2 Securely mount the generator in a visible accessible a...

Page 5: ...output is enabled Remote indicator Illuminates when any of the remote control functions are enabled Current Limited indicator Illuminates when the output current reaches the limit value RUN STOP Butt...

Page 6: ...continuous charging source When delivered the output voltage setpoint will be set to zero and the current limit set to its maximum value Enable the HV output press RUN STOP and increase the output vo...

Page 7: ...arameter value OK Move down to a lower menu level save parameter setting Pressing any of the setpoint adjustment buttons Voltage Current whilst using the menu will exit the menu system Remote Interfac...

Page 8: ...t rating 60 kV variants 0 60 kV DC 2 5 mA max Output connector type 4 x Fraser 30 60 kV tubular spring contact HV connector Remote interface connector 25 pin subminiature D type female Mating plug Amp...

Page 9: ...signal provided Provide remote on off signal Current limit set too low Increase current limit using Current buttons All LEDs flashing OVERLOAD shown on display Arcing or short circuit on HV output due...

Page 10: ......

Page 11: ......

Page 12: ...evon GB EX16 9DN T 44 0 1398 331114 F 44 0 1398 331411 E sales fraser antistatic co uk W www fraser antistatic com For more information about static and to view the full range of our products please v...

Reviews: