PERFORMANCE DATA - 3 TON
TP9C100C16MP13C
CF/CM/CU30C
0.93
1.01
0.95
TP9C100C16MP13C
CF/CM/CU36C
0.92
1.05
0.99
TPLC060A12MP13C
CF/CM/CU24A
0.96
1.00
0.90
TPLC060A12MP13C
CF/CM/CU24B
0.94
1.01
0.91
TPLC060A12MP13C
CF/CM/CU30B
0.95
1.01
0.94
TPLC060A12MP13C
CF/CM/36A
0.93
1.02
0.98
TPLC060A12MP13C
CF/CM/CU36B
0.93
1.04
0.98
TPLC080B12MP13C
CF/CM/CU24C
0.95
1.00
0.91
TPLC080B12MP13C
CF/CM/CU30B
0.95
1.00
0.93
TPLC080B12MP13C
CF/CM/CU30C
0.95
1.00
0.93
FURNACE MULTIPLIERS - 2 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW
TPLC080B12MP13C
CF/CM/CU36B
0.94
1.04
0.97
TPLC080B12MP13C
CF/CM/CU36C
0.93
1.04
0.98
TPLC080C16MP13C
CF/CM/CU24C
0.94
1.02
0.92
TPLC080C16MP13C
CF/CM/CU30C
0.95
1.02
0.94
TPLC080C16MP13C
CF/CM/CU36C
0.92
1.05
0.99
TPLC100C16MP13C
CF/CM/CU24C
0.94
1.02
0.92
TPLC100C16MP13C
CF/CM/CU30C
0.95
1.02
0.94
TPLC100C16MP13C
CF/CM/CU36C
0.92
1.05
0.99
FURNACE MULTIPLIERS - 2 TON (Continued)
Furnaces
Coil
T.C.
S.C.
KW
CONDENSER-ONLY DATA (OUTDOOR UNIT)
MODEL
SATURATED SUCTION
@ COMPRESSOR
Outdoor Ambient Temperature
65 °F
75 °F
85 °F
95 °F
105 °F
115 °F
125 °F
T (°F)
P (PSIG)
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
MBH
KW
HL19B3621S
35
107.4
27.75
1.50
28.62
1.70
29.48
1.89
30.35
2.09
31.21
2.28
32.08
2.48
32.94
2.68
40
118.6
32.73
1.52
32.56
1.72
32.38
1.93
32.21
2.13
32.03
2.34
31.86
2.54
31.68
2.75
45
130.4
37.71
1.54
36.50
1.75
35.28
1.96
34.07
2.18
32.85
2.39
31.64
2.60
30.42
2.82
50
143.0
42.69
1.56
40.44
1.78
38.18
2.00
35.93
2.22
33.67
2.44
31.42
2.67
29.16
2.89
55
156.3
47.67
1.58
44.38
1.81
41.08
2.04
37.79
2.27
34.49
2.50
31.20
2.73
27.90
2.96
60
170.3
52.65
1.59
48.32
1.83
43.98
2.07
39.65
2.31
35.31
2.55
30.98
2.79
26.64
3.03
Notes:
1. For Outdoor Unit (Condenser) performance only. Data does not include the effects of air handler power or heat.
2. Performance based on 15°F subcooling and 15°F superheat at the Outdoor Unit base valves.
a. Increase capacity by 1% for each 2°F increase in subcooling.
b. Decrease capacity by 1% for each 2°F decrease in subcooling.
3. Maximum recommended condensing temperature is 140°F.