Anytime working on or near the SubDrive Solar controller, or system:

• Securely cover the solar array with an opaque tarp.
• Turn OFF the external DC rated disconnect from the solar array to the SubDrive

Solar controller.

• Ensure AC power has been disconnected from the SubDrive Solar controller (if used).
• Wait

• Incorrect wiring of panels causing the Controller to be fused, blown/overloaded 

will void warranty.

 a minimum of 5 minutes after removing power from the SubDrive Solar 

controller before servicing.

IMPORTANT INFORMATION FOR INSTALLERS OF THIS EQUIPMENT!

THIS EQUIPMENT IS INTENDED FOR INSTALLATION BY TECHNICALLY QUALIFIED PERSONNEL. 
FAILURE TO INSTALL IT IN COMPLIANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES, 
AND WITHIN FRANKLIN ELECTRIC RECOMMENDATIONS, MAY RESULT IN ELECTRICAL 
SHOCK OR FIRE HAZARD, UNSATISFACTORY PERFORMANCE, AND EQUIPMENT FAILURE. 
FRANKLIN INSTALLATION INFORMATION IS AVAILABLE FROM PUMP MANUFACTURERS AND 
DISTRIBUTORS, AND DIRECTLY FROM FRANKLIN ELECTRIC.

ATTENTION

 

WARNING

!

SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT FROM FAILURE TO CONNECT THE MOTOR,
CONTROL ENCLOSURES, METAL PLUMBING, AND ALL OTHER METAL NEAR THE MOTOR OR 
CABLE TO A PROPER EARTH GROUND IN ACCORDANCE WITH LOCAL CODES, USING WIRE NO 
SMALLER THAN MOTOR CABLE WIRES. TO REDUCE RISK OF ELECTRICAL SHOCK, DISCONNECT 
POWER BEFORE WORKING ON OR AROUND THE WATER SYSTEM. DO NOT USE MOTOR IN 
SWIMMING AREAS.

 

CAUTION

!

 

WARNING

!

High voltages (both AC and DC) capable of causing severe injury or death by electrical shock 
are present in this unit. More than one disconnect switch may be required to de-energize 
the equipment before servicing. This unit should only be installed or serviced by technically 

Use the SubDrive Solar controller only with Franklin Electric 4-inch submersible motors as
specified in SubDrive Solar manual (see Table 6, pg. 26). Use of this unit with any other 
Franklin Electric motor or with motors from other manufacturers may result in damage to 
both motor and electronics.

Summary of Contents for SubDrive Solar

Page 1: ...SubDrive Solar Array Wiring Diagrams SOLAR SUBMERSIBLE PUMP CONTROLLER SOLAR SUBMERSIBLE PUMP CONTROLLER...

Page 2: ...N IS AVAILABLE FROM PUMP MANUFACTURERS AND DISTRIBUTORS AND DIRECTLY FROM FRANKLIN ELECTRIC ATTENTION WARNING SERIOUS OR FATAL ELECTRICAL SHOCK MAY RESULT FROM FAILURE TO CONNECT THE MOTOR CONTROL ENC...

Page 3: ...20 Amp 1000 v DC Isolator Pump Motor CMC4 10m Cable VE VE 6 Panel Solar Array VE VE Wiring Diagram 6 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp not to exceed 330VDC Maximum Voc not to...

Page 4: ...C4 10m Cable Branch Connector VE Branch Connector VE 3m Cable 12 Panel Solar Array 2 x Strings of 6 Panels 3m Cable VE VE Wiring Diagram 12 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp n...

Page 5: ...r 20 Amp 1000 v DC Isolator Pump Motor VE VE 6 7 8 9 Panels in Series VE VE Wiring Diagram 6 7 8 9 Panels SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp not to exceed 330VDC Maximum Voc not to e...

Page 6: ...C4 10m Cable Branch Connector VE Branch Connector VE 3m Cable 14 Panel Solar Array 2 x Strings of 7 Panels 3m Cable VE VE Wiring Diagram 14 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp n...

Page 7: ...C4 10m Cable Branch Connector VE Branch Connector VE 3m Cable 16 Panel Solar Array 2 x Strings of 8 Panels 3m Cable VE VE Wiring Diagram 16 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp n...

Page 8: ...C4 10m Cable Branch Connector VE Branch Connector VE 3m Cable 18 Panel Solar Array 2 x Strings of 9 Panels 3m Cable VE VE Wiring Diagram 18 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp n...

Page 9: ...4 10m Cable Branch Connector VE Branch Connector VE Parallel Connectors 27 Panel Solar Array 3 x Strings of 9 Panels VE VE Wiring Diagram 27 Panel SOLAR SUBMERSIBLE PUMP CONTROLLER Notes Maximum Vmpp...

Page 10: ...10 Notes...

Page 11: ...11 Notes...

Page 12: ...FE887 09 12 Franklin Electric Aust Pty Ltd 106 110 Micro Circuit Dandenong South Vic 3175 Tel 61 3 9799 5000 Toll Free 1300 FRANKLIN 1300 372 655 franklin electric com au...

Reviews: