background image

INTRODUCTION

EN

This instruction sheet provides you with the information required to safely 

own and operate your Little Giant product. Retain these instructions for future 

reference.
The Little Giant product you have purchased is of the highest quality work-

manship and material, and has been engineered to give you long and reliable 

service. Little Giant products are carefully tested, inspected, and packaged to 

ensure safe delivery and operation. Please examine your item(s) carefully to 

ensure that no damage occurred during shipment. If damage has occurred, 

please contact the place of purchase. They will assist you in replacement or 

repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO 

INSTALL, OPERATE, OR SERVICE YOUR LITTLE GIANT PRODUCT. 

KNOW THE PRODUCT’S APPLICATION, LIMITATIONS, AND POTENTIAL 

HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING 

ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE 

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR 

PROPERTY DAMAGE! 

SAFETY GUIDELINES

Make certain that the unit is disconnected from the power source before 

attempting to service or remove any component.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, 

kerosene, etc. Do not use in explosive atmospheres. Pump should only be 

used with liquids compatible with pump component materials.
Do not handle pump with wet hands or when standing on a wet or damp sur-

face or in water.
Do not pull the pump out of the water by the power cord when the pump is 

operating or connected to power source.
This pump is supplied with a grounding conductor and/or grounding type 

attachment plug. To reduce the risk of electric shock, be certain that it is 

connected to a properly grounded grounding type receptacle protected by a 

ground fault circuit interrupter.
In any installation where property damage and/or personal injury might result 

from an inoperative or leaking pump due to power outages, discharge line 

blockage, or any other reason, a backup system(s) and/or alarm should be 

used.
Support pump and piping when assembling and when installed. Failure to do 

so may cause piping to break, pump to fall, motor bearing failures, etc.
The National Electric Code (in the USA) and similar codes in other countries 

require a Ground Fault Circuit Interrupter (GFCI) to be installed in the branch 

circuit supplying fountain equipment rated above 15 volts.
This pump is intended for draining swimming pool covers only and should not 

be used if there are people in the pool.

ELECTRICAL CONNECTIONS

1.  Check the pump label for proper voltage required. Do not connect to voltage 

other than that shown.

2.  If pump is supplied with a 3-prong electrical plug, the third prong is to ground 

the pump to prevent possible electrical shock hazard. DO NOT REMOVE the 

third prong from the plug. Do not shorten the cord or cut the plug from the 

cord; this will void the warranty.

3.  If the cord is equipped with stripped lead wires, such as on 230v models, 

be sure that the lead wires are connected to a power source correctly. The 

green/yellow wire is the ground, and the other two are live.

OPERATION

  1. This pump must be operated with the volute intake below the liquid level.
  2. This pump can be placed in any position.
  3. The volute on this pump can be rotated 90° to allow for different pump 

orientations. To rotate the volute, remove the three volute screws (item 2). 

Remove and rotate the volute and gasket and reinstall the three screws in 

the additional holes in the front of the pump housing. 

SMALL SUBMERSIBLE

ENCAPSULATED PUMP

PE-1-PCP

   

NOTE:

 DO NOT USE EXCESSIVE TORQUE ON THE VOLUTE SCREWS; 

THIS COULD CAUSE THE HOLES TO STRIP.

  4. The weight of the pump must be supported adequately. DO NOT support the 

pump by the discharge connection alone. Pump may be supported by using 

the two mounting holes in the back of the pump. The holes are designed for 

#8 self-tapping screws. DO NOT exceed the hole depth of .37".

  5. Do not restrict the intake side of the pump; this may cause damage to the 

seal and may starve the pump. If you require reduced flow rates, place a 

valve on the discharge side of the pump or, if flexible vinyl tubing is used, 

a clamp on the tubing to restrict the flow.

  6. Do not let the unit operate dry. It is designed to be cooled by pumping fluid. 

You may damage the seal and the motor may fail if the pump is allowed to 

run dry.

  7. If the unit is going to be idle for a period of time, follow the cleaning instruc-

tions outlined in the SERVICE INSTRUCTIONS section. Do not let the unit 

freeze in the wintertime. This may cause cracking or distortion that may 

destroy the unit.

SERVICE INSTRUCTIONS

MAKE CERTAIN THAT THE UNIT IS DISCONNECTED FROM THE POWER 

SOURCE BEFORE ATTEMPTING TO SERVICE OR REMOVE ANY 

COMPONENT!

 1. This unit is permanently lubricated. Oiling is not required. The power cord 

cannot be replaced. In case of damage the whole unit must be replaced.

 2. Remove the intake screen from the pump. (Screen is snapped on and can be 

removed by pulling.) Then remove the three screws that attach the volute.

 3.  Lightly clean any corrosion or debris which may clog the impeller. Use a brush 

and penetrating oil and lightly scrape to remove encrusted material.

 4.  Turn the impeller by hand to make sure it turns freely. Set pump down so the 

pump and impeller are not touching anything. Plug the unit into GFCI circuit 

for 10 seconds to see if the impeller turns; a) If it is rotating and GFCI did not 

trip, unplug unit and install parts in reverse order in which they were removed. 

b) If it does not rotate, if pump is tripping circuit breakers, or not operating 

properly after cleaning, return to Little Giant or its authorized service center. 

DO NOT attempt repairs yourself.

 5. Be certain power cord is in good condition and contains no nicks or cuts.

INTRODUCTION

FR

Cette feuille d’instructions vous fournit les informations nécessaires pour 

entretenir et faire fonctionner votre produit Little Giant. Conserver ces directives 

afin de pouvoir les consulter plus tard.
Le produit Little Giant que vous avez acheté a été soigneusement fabriqué avec 

des matériaux de la plus haute qualité et a été conçu pour durer longtemps 

et offrir un service fiable. Les produits Little Giant sont soigneusement testés, 

inspectés et emballés afin d’en assurer la sécurité de fonctionnement et une 

livraison en bonne condition. Vérifier attentivement le produit afin de vous 

assurer qu’il n’a pas été endommagé pendant le transport. S’il est endom-

magé, veuillez contacter l’entreprise qui vous l’a vendu. Si une réparation ou 

un remplacement est requis, elle vous prêtera assistance.

LIRE ATTENTIVEMENT CES DIRECTIVES AVANT DE PROCÉDER À 

L’INSTALLATION, À L’UTILISATION OU À L’ENTRETIEN DU PRODUIT 

LITTLE GIANT. SE FAMILIARISER AVEC LES APPLICATIONS, LES LIMITES 

ET LES RISQUES POTENTIELS DU PRODUIT. ASSURER SA PROPRE 

PROTECTION ET CELLE DES AUTRES EN SUIVANT TOUTES LES RÈGLES 

DE SÉCURITÉ. LE NON-RESPECT DE CES DIRECTIVES PEUT ENTRAÎNER 

DES BLESSURES ET/OU DES DOMMAGES MATÉRIELS!

DIRECTIVES DE SECURITE

Veiller à débrancher l’appareil de sa source d’alimentation électrique avant 

l’entretien ou la dépose d’une ou de plusieurs piéces.
Ne pas pomper des fluides explosifs ou inflammables tels qu’essence, mazout, 

kérosène, etc. Ne pas employer dans une atmosphère comportant des risques 

de déflagration. La pompe ne doit servir qu’à pomper des liquides compatibles 

avec les matériaux utilisés pour la fabrication des éléments qui la composent.
Ne pas manipuler la pompe les mains humides, les pieds posés sur une sur-

face mouillée ou humide, ou les pieds dans l’eau.

Franklin Electric Co., Inc.

P. O. Box 12010

Oklahoma City, OK 73157-2010

888.956.0000 • Fax: 405.947.8720

www.LittleGiantWater.com

[email protected]

1