background image

2

 c.  Remove the felt washer (9) and shaft seal (8) from seal bore 

in the pump head.

 d.  Install new shaft seal and new felt washer into seal bore in the 

pump head.

 e. Press new retaining ring (10) into seal bore in the pump 

head.

 f. Place pump head onto motor shaft, carefully aligning the 

shaft seal inside diameter with motor shaft. There is a flat 
on the motor shaft and a mating flat on the impeller inside 
diameter. To fully seat the pump head onto the motor, the 
flats on the motor shaft and the impeller must be aligned. 
Rotate the pump head until the flats align and the pump head 
can be fully seated onto the face of the motor.

 g.  Align the pump head mounting holes with the mounting holes 

on the face of the motor. Reinstall the pump head mounting 
screws, tightening them evenly and snugly.

Repair Kits

555702

HRK-360S

555706

IRK-360

555713

IRK-360S

555714

ISRK-360S

Item

Description

Component Quantity

1

Screw, volute cover 

4

--

--

--

2

Volute cover, SST

1

--

--

--

3

Cover gasket, Nitrile 

2

2

2

2

4

Impeller, Buna-N w/SST insert

2

--

2

2

4

Impeller, Buna-N w/brass insert

--

2

--

--

5

Cam, SST

1

--

--

--

6

Gasket, fiber washer, cam screw 

1

--

--

--

7

Screw, cam

1

---

--

--

8

U-cup seal, Viton 

--

--

--

1

9

Felt washer

--

--

--

1

10

Internal retaining ring

--

--

--

1

11

Slinger washer, neoprene 

--

--

--

1

5

8

6

11

10

7

1

4

3

2

9

PumpAgents.com - Click here for Pricing/Ordering

PumpAgents.com - Click here for Pricing/Ordering

Summary of Contents for Little Giant 555702 HRK-360S

Page 1: ...wed by attaching the black negative lead wire to the ground battery terminal When disconnecting the pump first disconnect the black negative 1 lead wire from the battery ground terminal and then disconnect the red positive lead wire from the positive battery terminal 3 To operate properly the DC direct current version pump must be connected to a steady DC power source or a battery in good conditio...

Page 2: ...nd the pump head can be fully seated onto the face of the motor g Align the pump head mounting holes with the mounting holes on the face of the motor Reinstall the pump head mounting screws tightening them evenly and snugly Repair Kits 555702 HRK 360S 555706 IRK 360 555713 IRK 360S 555714 ISRK 360S Item Description Component Quantity 1 Screw volute cover 4 2 Volute cover SST 1 3 Cover gasket Nitri...

Page 3: ... area 6 Suction lift too high 1 Repair or replace 2 Replace defective part 3 Replace defective part 4 Replace defective part 5 Replace defective part 6 Lower pump Flow rate is low 1 Air leak or kink in hose 2 Defective cam or impeller 3 Incorrect voltage 4 Inlet clogged 1 Repair or replace 2 Replace defective part 3 Supply correct voltage 4 Clean inlet Shaft seal leaks 1 Seal worn 2 Groove worn in...

Page 4: ...ademark of Franklin Electric Co Inc For parts or repair please contact 1 888 572 9933 For technical assistance please contact 1 888 956 0000 www LittleGiantPump com CustomerService WTS fele com PumpAgents com Click here for Pricing Ordering PumpAgents com Click here for Pricing Ordering ...