background image

REPLACEMENT PARTS

MODEL/CATALOG NO.

ITEM

NO.

PART

NO.

DESCRIPTION

10E-CIA-SFS  

511350

10E-CIA-SFS  

511355

10S-CIA-SFS  

511550

10S-CIA-SFS  

511555

10S-CIA-SFS  

511565

2

110352 Cover assembly, 10ft, (115v)

1

 --

1

--

--

2

110353 Cover assembly, 25ft, (115v)

--

1

--

1

--

2

110354 Cover assembly, 25ft, (230v)

--

--

--

--

1

5

909022 Screw/washer, 10-24 x 5/8

4

4

4

4

4

6

928002 Seal ring, nitrile

1

1

1

1

1

7

950250 Switch  

1

1

1

1

1

8

902431 Screw, 8-18 x 1/2

2

2

2

2

2

11

950507 Capacitor assembly, 10-SFS

1

1

1

1

1

12

110101 Bracket, capacitor

1

1

1

1

1

13

106362 Float

1

1

1

1

1

14

902516 Screw, tapping, 10-24 x 1/2

1

1

1

1

1

15

110100 Retainer, float rod strap

1

1

1

1

1

16

929451 Push-in fastener

1

1

1

1

1

17

106381 Rod, float

1

1

1

1

1

18

106367 Strap, float

1

1

1

1

1

20

921103 Washer, lock

--

--

4

4

4

21

111415 Volute

--

--

1

1

1

22

109420 Base, screen

1

1

--

--

--

23

109153 Plate, base

1

1

--

--

--

24

909024 Screw/washer 5

5

--

--

--

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTIONS

Pump does not turn on.

Pump not plugged in.

Plug in pump.

Circuit breaker shutoff or fuse removed.

Turn on circuit breaker or replace fuse.

Accumulation of trash on float.

Clean float.

Float obstruction.

Check float path and provide clearance.

Defective switch.

Have pump serviced by authorized service center

Defective motor.

Have pump serviced by authorized service center.

Pump will not shut off.

Float or float rod obstruction.

Check float and float rod path and provide clearance.

Pump is air locked.

Shut power off for approximately 1 minute, then restart. Repeat several times 
to clear air from pump.

Liquid inflow matches pump capacity.

Larger pump required.

Defective switch.

Disconnect switch, check with ohmmeter. Open-infinitive resistance 
closed zero.

Pump runs but does not 
discharge liquid.

Check valve installed backwards.

Check flow indicating arrow on check valve body to ensure it is installed 
properly.

Check valve stuck or plugged.

Remove check valve and inspect for proper operation.

Lift too high for pump.

Check rating table.

Inlet to impeller plugged.

Pull pump and clean.

Pump is air locked.

(See corrective action above.)

Pump does not deliver 
rated capacity.

Lift too high for pump.

Check rated pump performance.

Low voltage, speed to slow.

Check for proper supply voltage to make certain it corresponds to 
nameplate voltage.

Impeller or discharge pipe is clogged.

Pull pump and clean. Check pipe for scale or corrosion.

Impeller wear due to abrasives.

Replace worn impeller.

Pump cycles continually.

No check valve in long discharge pipe allowing 
liquid to drain back into basin.

Install a check valve in discharge line.

Check valve leaking.

Inspect check valve for correct operation.

Basin too small for inflow.

Install larger basin.