Motor Lead Installation
NOTE: The included motor in the Fhoton™ SolarPAK does come with a factory installed individual conductor lead. To replace or install a
new lead, please refer to the Franklin Electric AIM Manual for further information on motor lead installation and replacement
Fault Codes and Troubleshooting
The Fhoton™ Drive will attempt to operate the pump to deliver water even under adverse conditions. To ensure years of reliable service,
it must also protect the system components from conditions that might result in equipment damage. When adverse conditions arise, the
controller will continue to deliver as much water as possible at a reduced output if necessary, and will shut down only in extreme cases.
Full operation will resume automatically whenever abnormal conditions subside.
Error conditions may suspend certain features, reduce output, or shut down operation of the system for varying amounts of time depending
on the nature and severity of the error. Problems that merely reduce features or performance generally restore full operation when the
trouble condition subsides without stopping the pump or flashing an error code. An error code is displayed by the flashing LED light.
If the drive has stopped to indicate a fault code, the associated time-out delay will vary depending on the nature of the fault.
See Table 6 for the list of Fault Codes and possible causes.
For Fuse Replacement Use
Fuse: F1 – R/C (JFGA.E339112)
LITTELFUSE INC, model SPF020, (rated 1000VDC, 20A, 20kA interrupt).
Alternate: R/C (JFHR2.E342342)
PHOENIX CONTACT GMBH & CO. KG, model FUSE 10.3x38 20A, (rated 1000VDC, 20A, 30kA interrupt).
Alternate: R/C (JFGA.E335324)
BUSSMANN, model PV-20A10F, (rated 1000VDC, 20A, 50,000A interrupt).