background image

SAFETY WARNINGS

BEFORE OPERATING OR 
INSTALLING THIS PUMP, READ 
THIS MANUAL AND FOLLOW 
ALL SAFETY RULES AND 
OPERATING INSTRUCTIONS. 

 SAFETY 

CAREFULLY READ THESE SAFETY 
MESSAGES IN THIS MANUAL AND 
ON PUMP.

 WARNING - ELECTRICAL PRECAUTIONS

All wiring, electrical connections, and system grounding must 
comply with the National Electrical Code (NEC) and with any local 
codes and ordinances. Employ a licensed electrician.

 WARNING - RISK OF ELECTRICAL SHOCK

• 

Have an electrician provide electrical power to the motor.

• 

Motor must be grounded and terminal cover in place to 
reduce electrical shock hazard.

• 

Keep motor operating area as dry as possible.

•  

Always disconnect power before servicing.

• 

Not investigated for use in swimming pool areas.

• 

FBSEF series is capable of pumping liquid fertilizers. Re-
view all chemical manufacturers safety precautions before 
handling. Do not breathe or ingest fumes or chemicals.

a)

 

PUMP LOCATION:

 The pump should be installed in a 

clean, dry and ventilated location which provides adequate 
drainage, room for servicing and protection from freezing 
temperatures. It should be bolted down evenly on a good 
foundation, preferably concrete, to prevent the development of 
unnecessary stress. Locating the pump as close as possible 
to the source of water supply reduces the friction losses in 
the suction pipe and provides for maximum capacities.

b)

 

SUCTION PIPE:

 It is recommended that only new clean 

pipe or hose be used and the size be the same as the pump 
suction tapping. If the pump is installed any appreciable 
distance away from the source of water supply, the suction 
pipe should be increased by one size (this would increase 
the priming time). The suction pipe must always slope 
upwards from the water source to the pump to avoid air 
pockets in the line. In cases where the pump has to be 
reprimed often and it is not necessary that a lot of water be 
delivered (e.g. draining seepage from behind a cofferdam), 

it is advisable to use a 90° or 45° elbow on the suction line. 
This enables the pump to prime sooner and also prevents 
kinking of the hose. In cases where a maximum volume 
of water is required over a prolonged period of time, the 
suction line should be led almost horizontally to the pump. 
Thread compound should be used on all pipe joints and 
connections should be thoroughly tightened. A strainer 
should be connected to the bottom end of the suction 
pipe and it should be well submerged at all times.

c)

 

WIRING:

 It is recommended that a separate circuit be led 

from the distribution panel to the pump unit. A properly 
fused disconnect switch is to be installed in the line, 
making sure that the correct gauge of cable is used to 
carry the load. Very long leads will require a larger cable. 
For all three phase motors a separate manual thermal 
overload switch or a magnetic starter having the proper 
size heater elements must be installed. An electrician 
should be employed to do the wiring. 

APPLICATION

This pump is suitable for installations where the vertical distance 
from the pump to the water level does not exceed 25 feet. In 
off-set installations, friction losses in the suction pipe must be 

taken into consideration. The FBSEF-series pumps are suitable 
for transferring liquid fertilizer.

INSTALLATION

 CAUTION

• 

DO NOT OPERATE THIS PUMP DRY!

• 

Review instructions before operating.

OPERATION - PRIMING THE PUMP

 WARNING:

 

  DO NOT RUN THE PUMP BEFORE PRIMING IT. THE SEAL AND IMPELLER COULD BE  

 

 

 PERMANENTLY 

DAMAGED.

a)

 

PRIMING:

 Remove the priming plug located on the top of 

the casing and fi ll the pump casing with water. Replace 
the priming plug.

b)

 

IMPELLER ROTATION:

 The impeller must rotate in a 

counter-clockwise direction as seen facing the pump from 
the front of the casing. In the event of wrong rotation for 

FBSE AND FBSEF SERIES 
Self Priming Centrifugal Pumps

OWNER'S MANUAL

electric motor models, refer to the instructions furnished 
with the motor. The rotation of three phase motors can be 
changed by interchanging any two lead wires.

c)

 

STARTING THE PUMP:

 Never operate the pump dry as 

this may damage the seal. If an exceptionally long suction 
line is used, the water in the pump casing may become 

Summary of Contents for FBSE Series

Page 1: ...the suction line This enables the pump to prime sooner and also prevents kinking of the hose In cases where a maximum volume of water is required over a prolonged period of time the suction line shou...

Page 2: ...as dry as possible Always disconnect power before servicing Not investigated for use in swimming pool areas a LUBRICATION 1 The pump requires no lubrication 2 Refer to instructions provided by the mo...

Page 3: ...lt the adapter assembly onto the motor Make sure that the flinger 10 is on the shaft CAUTION Be careful not to damage the ceramic seat or shaft when reassembling sleeve to the motor 4 Slide the sleeve...

Page 4: ...er or 4 Product was damaged as a result of negligence abuse accident misapplication tampering alteration improper installation operation maintenance or storage nor to an excess of recommended maximums...

Page 5: ...la conduite Dans les cas o la pompe doit tre r amorc e souvent et qu un grand d bit d eau n est pas n cessaire ex l extr mit biseaut e en premier il est conseill d utiliser un coude de 90 ou de 45 da...

Page 6: ...s pouces S assurer que la surface polie donne vers l ext rieur 3 Monterl adaptateursurlemoteur essenceoulemoteur lectrique en prenant bien soin de na pas endommager l embase de c ramique 4 Utiliser un...

Page 7: ...cavalier 10 est install sur l arbre MISE EN GARDE Faire attention de ne pas endommager le si ge de c ramique ou l arbre en fixant le manchon au moteur 4 Faire glisser le manchon 11 et le joint 8 sur l...

Page 8: ...tion de proc dures d installation d op ration d entretien ou d entreposage non conformes ou pour cause d utilisation exc dant les maximums recommand s tel que stipul dans les instructions concernant l...

Page 9: ...adecuado en la l nea asegur ndose se use el calibre de cable adecuado para llevar la carga Los cables muy largos tendr n que ser de mayor calibre Para los motores trif sicos se debe instalar un inter...

Page 10: ...or en el motor el ctrico o de gasolina teniendo mucho cuidado de no da ar el asiento de cer mica 4 Utilice un jab n l quido sobre el sello rotativo y desl celo sobre el eje con el anillo con el lado b...

Page 11: ...e la mano 3 Atornille el conjunto adaptador al motor Aseg rese de que el tirador 10 est en el eje PRECAUCI N Sea cuidadoso en no da ar el asiento cer mico o el eje al rearmar el manguito al motor 4 De...

Page 12: ...producto result da ado por negligencia abuso accidente aplicaci n indebida modificaci n alteraci n instalaci n inadecuada operaci n mantenimiento o almacenamiento o como resultado del abuso de los l...

Reviews: