Summary of Contents for E Series

Page 1: ...r operation procedures and all applicable codes may result in the following hazards Risk of severe injury or death by electrical shock Ground motor before connecting to power supply To reduce risk of electrical shock disconnect power before working on or around the system More than one disconnect switch may be required to de energize the equipment before servicing Wire pump system for correct volt...

Page 2: ...ere is an adequate flow of water over the motor for cooling purposes is ensured Determine the correct pump setting from the driller s record taking into account the static water level and the draw down at the proposed pumping rate Pressure Tank Pressure Switch Gate Valve Service Pipe Pressure Gauge Pressure Relief Valve Spring Loaded Check Valve See Wiring Diagrams Sanitary Well Seal or Pitless Ad...

Page 3: ...nd apply power momentarily 8 Ensure pump rotation is clock wise when viewed from pump discharge 9 Place the motor and pump labels in the circuit breaker box for future reference Physical Installation Refer to Typical Installation on page 2 1 Confirm that the motor s lead wires are secure under the pump s lead guard 2 Install a pressure tank per manufacturer s recommendations 3 Attach a 3 16 diamet...

Page 4: ... well and above well screen or casing perforations 9 Test the well Refer to Well Test on page 4 10 Place a sanitary well seal or pit less adapter over top of well per manufacturer s recommendations Well Test 1 Install a partially opened gate valve on the end of the pipe 2 Start the pump and slowly open valve to full flow 3 If the discharge water is not clear within 30 minutes stop pump and take ne...

Page 5: ...trical rating of the motor For 3 wire single phase pumps check the control box Incorrect rotation 3 phase Interchange any two leads at the magnetic starter Pump cycles too fre quently Pressure drop between pres sure switch and tank Check system for a plumbing leak and correct as necessary Cut in or Cut out pressure too high Follow manufacture s instructions to properly set the on off cycle of the ...

Page 6: ...ting ft m Drop Pipe Size Wire Size pump to control box Wire Size control box to power source Horizontal Offset between well house Materials of Construction 3 Phase Panel Info Standard Soft Start or VFD Power Supply Options Utility Generator or Alternative Energy Source Make of Pump Amps HP Volts Ph Make of Control Box HP Volts Power Supply Volts HZ Pressure Switch PSI Cut in Cut out ...

Page 7: ...NOTES ...

Page 8: ...800 348 2420 franklinwater com For technical assistance parts or repair please contact Form 106259101 Rev 003 06 20 Copyright 2020 Franklin Electric Co Inc All rights reserved ...