background image

Table of contents

1  General information 

3

1.1 Introduction 

3

1.2 Safety 

3

2  Intended use  

4

3  Structure 

4

4  Scope of delivery 

4

5  Technical data 

4

5.1 Connection options 

4

5.2 Dimensional drawing 

4

5.3 Schematic connection diagram 

5

6  Wiring diagrams 

5

6.1 Modbus (connection to the ventilation unit)  

6

6.2 Fire / smoke alarm input  

6

6.3 Humidistat input  

7

6.4 Standby input  

8

6.5 External fan activation input 

9

6.6 Error messages output 

9

7  Warranty 

10

8  Liability 

10

9  Disposal 

10

All information provided in this publication is generally up to date at the time of printing. Moreover, this publication was prepared with the greatest possible care. However, we cannot rule out 

printing errors or translation mistakes. Furthermore, we reserve the right to change products, specifications and other information, or changes may be necessary due to legal, material or other 

technical requirements, which no longer could be considered for this publication. For this reason, we are unable to accept any liability if this is based solely on the information contained in this 

publication. Instrumental in connection with information about products or services are always the purchase order, the concrete product purchased and the related documentation or the 

information provided by our specialist staff in the specific case.

Installation instructions / operating instructions – profi-air flat / flex connection box

2

Summary of Contents for profi-air 180 Flat

Page 1: ...profi air flat flex connection box Installation instructions operating instructions Building Technology www fraenkische com...

Page 2: ...tion was prepared with the greatest possible care However we cannot rule out printing errors or translation mistakes Furthermore we reserve the right to change products specifications and other inform...

Page 3: ...oth and efficient operation 1 2 Safety If used as intended the unit is safe and reliable to operate The construction and design are state of the art and comply with all relevant DIN VDE regulations an...

Page 4: ...housing which is installed near the ventilation unit 4 Scope of delivery Connection box incl 4 PG threaded connectors Approx 2 5 m of connection cable wired with RJ25 connector plug to connect to the...

Page 5: ...ive Not active Fire smoke alarm input Not active Not active Modbus connection to the ventilation unit and or connection to the control unit 5 3 Schematic connection diagram 5 Technical data 6 Wiring d...

Page 6: ...e fire smoke alarm with a relay output When delivered the contact is furnished with a bridge If this contact is interrupted by e g a triggered fire smoke alarm the control system deactivates the venti...

Page 7: ...ue at the room humidistat is exceeded the control system switches the ventilation unit to mode 3 If the wiring is arranged in parallel several room humidistats can be connected to the contact The digi...

Page 8: ...il driver The input can be used to connect a standby switch to the ventilation unit Contact closed ventilation unit in operation Contact open ventilation unit out of operation If the system has been s...

Page 9: ...H T1GTC 16V Standby Switch Hygro stat Fail Alarm Filter Alarm 12V SDA SCL TFAH T2AH T2AC 0 10V 0 10V 0 V 0 V 0 V 0 V 0 V 0 V 0 V 0 V 0 10V 0 10V The input can be used to control the fan mode of the ve...