Overview of Installation 

There are three main components to the system, the 
dispensing head, the canister and the heating tank. The 
dispensing head comes with three 1/4” copper tubes and 
one silicone tube. The two shorter (12”) copper tubes are 
connected to the incoming water supply via the canister. 
The supply to the cold side may be diverted through a 
chiller before the dispensing head, if required. The 
longer (18”) copper tube is connected to the inlet of the 
tank. The silicone tube is connected to the outlet of the 
tank using the hose connec tor. 
 

Preparing for the Installation

 

As with any sink  related device, it is much easier to 
mount the dispens ing head of this system onto the sink 
before the sink  is mounted into the countertop. A 
mounting hole of 1 3/8” diameter (standard sink ledge 
drilling) is required. 
 
It is always recommended to take the c omponents and 
locate their optimum positions before starting the 
installation.  
 

IMPORTANT: Do not plug in the unit until all water 
connections have been made and the tank is filled 
completely. 
 
Making the Supply Provision 

Provide a branch compression connection for a 3/8” 
supply tube. This should be done with a conventional tee 
and the shut-off valve provided. Flush the pipework 
before installing. 
 

Mounting the Dispensing Head 

The copper tubes are coiled for packing and must be 
carefully straightened before installation. Feed the tubes 
and shank through the hole in the sink ledge or counter. 
Assemble the clamp plate locking washer and back nut 
(hexagon to the top for thin sinks) fingertight. Turn the 
dispensing head and the spout until the handles and 
spout are in the required position for use and fully tighten 
the backnut, this will lock the spout in position. 
 

Seasonal Shutdown 

 

If you plan to be away from home for ex tended periods  
the following procedure must be carried out: 

Operate the hot lever until the water runs cold. 

Shut-off the main water supply. A stop valve was 
supplied with the system for this purpose, and will be 
found located on the adjacent pipe work . 

Operate both levers to confirm that the water supply is 
turned off, and to release the pressure in the system.  

 
 
 
 

Troubleshooting 

Should your dispenser not work  correctly, check  the list 
below before c alling for service. The following things are 
not covered by the warranty. 
 

[WARNING! Do not operate both levers at the same 
time as this can build up pressure in the heating 
tank causing the bladder to expand and eventually 
burst. Such damage is not covered by the warranty] 
 
Water is not hot: 

Check if electrical supply to heating tank is plugged in. 
Turn temperature control knob clock wise as far as 
possible. 
 
Test the temperature again after 15 minutes. 
Check if fuse is blown or c ircuit breaker is open. 

 
Hot water continuously drips or sputters from spout: 

For safety reasons this faucet may drip or splutter after 
use. This venting prevents a build-up of pressure in the 
heating tank. If this becomes excessive; Turn the control 
knob counter-clockwise to lower temperature. Check  the 
tubes connecting the faucet to the storage tank are not 
kinked. 
 

Check the condition of the canister and clean or 
replace if necessary. 
 
Water does not flow: 

Check the shut off valve is open. 
Check if supply tube is kinked. 

Spare Parts 

For out-of-warranty maintenance and repairs, we recommend you employ 
a Registered Plumber. 
 
Before ordering spare parts , determine the correct reference number from 
the exploded diagram. Quote this number, and where appropriate, the 
color of your faucet. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Limited Warranty 

Congratulations on the purchase of a Franke 
product. Franke is one of the world’s largest 
manufacturers of kitchen systems. Our 
products are manufactured using the highest 
degree of technology quality and design. As 
a result we are proud to offer the following 
warranty. 

Franke Inc. Kitchen Systems Division, 
warrants the quality of its water dispensing 
systems to be free from manufacturing 
defects for a period of 

five 

years from the 

date of purchase. 

This warranty applies only to the original 
owner, providing the product has been 
installed in accordance with our installation 
instructions, used as recommended and in a 
normal residential application. In the event of 
a warranty claim, the owner will be required 
to provide proof of purchase. This warranty 
covers all components necessary to restore 
the product to good working condition. 
Franke reserves the right to inspect the 
installation prior to the replacement of the 
product or component part. 

This warranty does not cover misuse or 
abuse, accidental damage, scuffs or 
scratches, abnormal usage, negligence or 
damage caused by improper maintenance or 
cleaning. Normal wear of parts is excluded 
from warranty. Damage caused by impurities 
or acts beyond our control are not covered. 
Any product or part which has been repaired 
or altered in any manner outside of Franke’s 
factory, unless previously authorized in 
writing by Franke, will void warranty. 

Any 

replacement excludes transportation and 
any labor reinstallation costs. 

This 

warranty does not allow recovery of 
incidental or consequential damages such as 
loss of use, delay, property damage or other 
consequential damage, and Franke accepts 
no liability for such damages. 

The Franke warranty is limited to the above 
condition and to the warranty period 
specified herein and is exclusive. Franke 

DISCLAIMS 

all other warranties, expressed 

or implied, including the 

IMPLIED 

WARRANTIES OF MERCHANTABILITY 
AND/OR FITNESS FOR A PARTICULAR 
PURPOSE. 

This warranty gives you specific 

legal rights which may vary from state to 
state. 

What you must do: 

The purchaser should 

retain original proof of purchase.  Failure to 
do so may void this warranty.

 

WARNING: Do NOT use tools
or  modify  the  Push  Fit
Connections  as  this  could
d a m a g e   t h e   c o n n e c t i o n
r e s u l t i n g   i n   l e a k s   a n d
will void the warranty.

Diagram B

Push Fit Connections

Connections To
Heating Tank

*Cut to Length for
Franke Canister

Silicone Tube
Kit - 2-023

Spout & Shank
3-010* - LB2200 Model
3-011* - LB3200 Model
3-012* - LB4200 Model

Clamp Plate - 10115

Cold Valve & Seat Set - 2-015
Hot Valve & Seat Set - 2-014

Flow Straightener
10159

Lever Kit - 3-002*

End Cap - 10166*

Lever End
10170* - LB2200 Model
10171* - LB3200 Model
10172* - LB4200 Model

Cover
10167* - LB2200 Model
10168* - LB3200 Model
10169* - LB4200 Model

10321

10306

Backnut - 92022

10322

WARNING: Do NOT

Use Tools

*Where Indicated Specify Color

Reviews: