Charcoal filter (recycling version) 

•  This filter cannot be washed or regenerated. It must be replaced when the EF appears on the 

display or at least once every 4 months.  

Activation of the alarm signal  
•  In the recycling version hoods the filter saturation alarm must be activated during the instal-

lation or later. 

•  Switch off the hood and the lights. 
•  Disconnect the hood from the mains supply. 
•  When restoring the connection press and hold B-key. 
•  When releasing the key two rotating rectangles appear on the display. 
•  Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: 
  •  2 flashes with EF - charcoal filter saturation alarm ACTIVATED 
  •  1 flash with EF - charcoal filter saturation alarm DEACTIVATED.  

 

REPLACING THE CHARCOAL FILTER 

Reset of the alarm signal 
•  Switch off the hood and the lighting. If the 24h-function has 

been activated this has to be deactivated. 

•  Press the E-key until the display is unlit. 

Replacing of the filter  
•  Open the comfort panels pulling them downwards. 
•  Remove the metal grease filters. 
•  Remove the saturated charcoal filter by releasing the fixing 

hooks 

•  Fit the new filter and fasten it in its correct position. 
•  Put the metal grease filters in their seats. 
•  Close the comfort panels.  

 

 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 
•  Remove the 2 screws fixing the Lighting support, and pull it 

out of from the Hood. 

•  Extract the lamp from the Support. 
•  Replace with another of the same type, making sure that the 

two pins are properly inserted in the lamp holder socket holes. 

•  Replace the Support, fixing it in place with the two screws re-

moved as above.  

 

 

Summary of Contents for ftu 3807 w xs - in2

Page 1: ...Instructions for use and installation Cooker Hood FTU 3807 WXS 70H FTU 3807 P WXS 70H...

Page 2: ...EN 3 3 Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS 18 CHARACTERISTICS 19 INSTALLATION 20 USE 24 MAINTENANCE 25...

Page 3: ...h naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be cont...

Page 4: ...uipped with the Exhaust Group 7 1 tube in PVC 8 1 Directioned grid 8c 1 Air outlet reduction 120mm 9 1 Reduction flange 150 120 mm Ref Q ty Installation components 11 4 Small blocks 10 12a 4 Screws 5...

Page 5: ...hich the hood is to be fitted a Horizontal line at a minimum of 826 mm above the Cooker Top As indicated mark a reference point at 100 mm to the right of the vertical reference line Repeat this operat...

Page 6: ...air outlet hole in the wall proceed in accor dance with the scheme in the paragraph concerning the wall drilling In case the connection is made with a 120 mm pipe insert the reduction flange 9 on the...

Page 7: ...it laterally with the 4 12b screws Cover the screw seats with the plugs 13 supplied with the hood Recycling version Remove the pre cut piece Lean the hood body on the support and fix it laterally wit...

Page 8: ...g them towards the back of the group and pulling down at the same time Being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Connect the...

Page 9: ...his key for about 3 seconds The indication is visible only when the motor is off Indicates the 24 function The spot down on the right side flashes and the motor is on Once the process is finished the...

Page 10: ...ull the Comfort Panel to open it Disconnect the panel from the hood canopy by sliding the fix ing pin lever The comfort panel must never be washed in a dishwasher Clean the outside using a damp cloth...

Page 11: ...Cleaning the filters Pull the comfort panels to open them Remove the filters one by one pushing them towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of...

Page 12: ...er saturation alarm DEACTIVATED REPLACING THE CHARCOAL FILTER Reset of the alarm signal Switch off the hood and the lighting If the 24h function has been activated this has to be deactivated Press the...

Page 13: ......

Reviews: