Installing of the chimney and fixing of the hood
When the hood is installed in recycling version the chimney has to be positioned with the slots upwards.
When the hood is installed in ducting version it has to be positioned in the opposite way.
• Place the chimney on the frame and fix it to the upper part of it with the earlier removed screws. When
installing the hood in recycling version make sure that the slots correspond to the air outlet of the recycling
air outlet piece 15.
• Open the lighting unit by slightly pulling the notch. Remove the unit from the hood by sliding the fixing pivot.
• Remove the filter pushing it towards the back side of the hood unit and simultaneously pulling downwards.
• Remove possible charcoal filters.
• In order to fix the hood body to the frame insert the 4 screws 12f in their seats. It is necessary to leave at
least 4-5 mm gap between the screw heads and the frame plate.
• Hook the hood canopy to the frame and turn it to the left until it reaches the stop, then lock the screws
immediately to prevent he hood canopy from falling out accidentally.
Electrical connection
• Connect to hood to the mains supply through a double pole switch with at least 3 mm clearance between
the contacts.
• Make sure that the connecting piece of the cable is correctly put in the socket.
• Connect the Cmd-connectors of the controls.
• Connect the Lux-connectors of the lighting system.
• In the recycling hood put the charcoal filter in its place.
• Put the metal grease filter and the confort panel into their proper seats